Контрольно-измерительные приборы и оборудование / 7MB
7MB1946-8AA
TEMPERATURE-CONTROLLED, HEATED SAMPLE GAS LINE FOR OPERATING TEMPERATURES UP TO 200 CEL, TEMPERATURE CONTROL VIA THE CONTROLLER OF THE FIDAMAT, WITH FE-CUNI THERMOCOUPLE
7MB1946-8AC
TEMPERATURE-CONTROLLED, HEATED SAMPLE GAS LINE FOR OPERATING TEMPERATURES UP TO 200 CEL, TEMPERATURE CONTROL VIA THE TEMPERATURE CONTROLLER OF THE FIDAMAT, WITH FE-CUNI THERMOCOUPLE AND 2 PT 100 RESISTANCE THERMOMETERS
7MB1946-8AB
TEMPERATURE-CONTROLLED, HEATED SAMPLE GAS LINE FOR OPERATING TEMPERATURES UP TO 200 CEL, TEMPERATURE CONTROL VIA THE TEMPERATURE CONTROLLER OF THE FIDAMAT, WITH FE-CUNI THERMOCOUPLE AND PT 100 RESISTANCE THERMOMETER
7MB1903-.....-1BA1
MESS- UND REGELEINRICHTUNG TACTOMAT MIT ULTRAMAT 22 FUER 2 MESSKOMPONENTEN, OHNE KONDENSATABSCHEIDER
7MB1904-....0-...1
MESS- UND REGELEINRICHTUNG TACTOMAT MIT ULTRAMAT 5E, GASWEGE SCHLAUCH, VERGLEICHS- KAMMER NICHT BESTROEMT, MESSGASANSCHLUESSE 1/4-18 NPT INNENGEWINDE
7MB1952-.....-....
Set FIDAMAT EX Standard system for operation of an FIDAMAT in a EX certified environment according to ATEX category 3G (Zone 2)
7MB1905-0....-..A1
MESS- UND REGELEINRICHTUNG TACTOMAT MIT OXYMAT 5E, MIT MESSKAMMER AUS STAHL X 10 CRNIMOTI 1810,W.-NR.1.4571
7MB1957-.....-....
Standardized SIEMENS Continuous Emission Monitoring System (CEMS), compliant with European emission control guidelines
7MB2355-.....-....
gas analyzer ULTRAMAT 23 for measurement of 1 infrared components and oxygen German Technical Inspectorate
7MB2357-.....-....
Gas analyzer ultramat 23 for measurement of 2 infrared Components and oxygen conc. TUEV
7MB2358-.....-....
Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen conc. TUEV
7MB3040-.....-....
CALOMAT 7 module for the measurement of gases in binary or quasi-binary gas mixtures for installation into base unit SIPROCESS GA700
7MB3010-.....-....
ULTRAMAT 7 module for measuring IR-absorbing gases for installation into base unit SIPROCESS GA700
7MB1943-2DB54
Buenox2+ converter 115V with reactor cartridge with bypass valaves 19-inch rack
7MB1943-2FA16
unheated extension pipe for sample gas probe Typ G3/4, Material 1.4571, Length 500 mm
7MB1943-2DB53
Buenox2+ converter 230V with reactor cartridge with bypass valaves 19-inch rack
7MB1943-2FA02
Heated sample gas probe with ball valve for manual shut-off, without backflushing, without cal. gas connection, weatherproof cover and heating, Temperature control range: From 50 to 200 Deg C Supply voltage 230V 50/60Hz
7MB1943-2FA14
sampling pipe made of PVDF for sample gas probe with Demister made of ETFE Length 800 mm
7MB3027-.....-....
OXYMAT 7 module, special application for oxygen measure ment for installation into base unit SIPROCESS GA700
7MB1943-2FA10
unheated extension pipe for sample gas probe Typ G3/4, Material 1.4571, Length 700 mm
7MB1943-2FA11
unheated extension pipe for sample gas probe Typ G3/4, Material 1.4571, Length 1000 mm
7MB1943-2FA06
Heated sample gas probe with ball valve with pneumatic actuator, controlled by customer, with backflushing, without cal. gas connection, heated air storage tank, weatherproof cover and heating, Temperature control range:
7MB1943-2FA04
Heated sample gas probe with ball valve with pneumatic actuator, controlled by customer, with backflushing, without cal. gas connection, unheated air storage tank, weatherproof cover and heating, Temperature control range:
7MB1943-2FA03
Heated sample gas probe with ball valve for manual shut-off, without backflushing, with cal. gas connection 6mm, weatherproof cover and heating, Temperature control range: From 50 to 200 Deg C Supply voltage 230V 50/60Hz