Энергетика PTD / 7VH
7VH1712
DRUCKSCHALTER-RELAISKOMBINATION FLACHBAUGRUPPENAUSFUEHRUNG MELDEKREIS 2S GEBRUECKT + 4S AUSLOESEKREIS 2S + 4S NENNSPANNUNG DC 48 V
7VH1625
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 216) MELDEKREIS 1OE, 1S AUSLOESEKREIS 2S + 4S NENNSPANNUNG DC 125 V
7VH6001-0EA10-0AA0
ANALOG SINGLE-PHASE HIGH IMPEDANCE DIFFERENT. RELAY BINARY INPUT VOLTAGE:24 TO 250V FOR RESET OF LOCKOUT PICKUP VOLTAGE SETTABLE VIA RESISTORS WITH VARISTOR UP TO 125 VEFF: 600A/1S/S256 WITH INTEGRATED CONVERTER: 24V TO 250V DC, 80V TO 264V AC IN HOUSING 7XP20 FOR PANEL FLUSH MOUNTING OR CUBICLE MOUNTING (WITH TERMINALS AT THE BACK) MAX. PICKUP VOLTAGE 60V (STEPS OF 6V) LOCKOUT OF TRIP COMMAND
7VH6000-0EA10-0AA0
ANALOG SINGLE-PHASE HIGH IMPEDANCE DIFFERENT. RELAY BINARY INPUT VOLTAGE:24 TO 250V FOR RESET OF LOCKOUT PICKUP VOLTAGE SETTABLE VIA RESISTORS WITHOUT VARISTOR WITH INTEGRATED CONVERTER: 24V TO 250V DC, 80V TO 264V AC IN HOUSING 7XP20 FOR PANEL FLUSH MOUNTING OR CUBICLE MOUNTING (WITH TERMINALS AT THE BACK) MAX. PICKUP VOLTAGE 60V (STEPS OF 6V) LOCKOUT OF TRIP COMMAND
7VH6002-0EA20-1AA0
ANALOG SINGLE-PHASE HIGH IMPEDANCE DIFFERENT. RELAY BINARY INPUT VOLTAGE:24 TO 250V FOR RESET OF LOCKOUT PICKUP VOLTAGE SETTABLE VIA RESISTORS WITH VARISTOR 125 VEFF-240VEFF: 600A/1S/S1088 WITH INTEGRATED CONVERTER: 24V TO 250V DC, 80V TO 264V AC IN HOUSING 7XP20 FOR PANEL FLUSH MOUNTING OR CUBICLE MOUNTING (WITH TERMINALS AT THE BACK) MAX. PICKUP VOLTAGE 240V (STEPS OF 24V) LOCKOUT OF TRIP COMMAND, DIFFERENTIAL CURRENT MONITORING
7VH3001-0MA
SPANNUNGSANZEIGER FLACHBAUGRUPPE MIT MELDETEIL HILFSSPANNUNG AC 50HZ 100/110V
7VH1814
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 217) MELDEKREIS 2S GEBRUECKT AUSLOESEKREIS 2S NENNSPANNUNG DC 110 V
7VH1802
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 217) MELDEKREIS 2S AUSLOESEKREIS 2S GEBRUECKT NENNSPANNUNG DC 48 V
7VH1812
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 217) MELDEKREIS 2S GEBRUECKT AUSLOESEKREIS 2S NENNSPANNUNG DC 48 V
7VH1825
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 217) MELDEKREIS 1OE, 1S AUSLOESEKREIS 2S NENNSPANNUNG DC 125 V
7VH1826
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 217) MELDEKREIS 1OE, 1S AUSLOESEKREIS 2S NENNSPANNUNG DC 220 V
7VH1715
DRUCKSCHALTER-RELAISKOMBINATION FLACHBAUGRUPPENAUSFUEHRUNG MELDEKREIS 2S GEBRUECKT + 4S AUSLOESEKREIS 2S + 4S NENNSPANNUNG DC 125 V
7VH1801
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 217) MELDEKREIS 2S AUSLOESEKREIS 2S GEBRUECKT NENNSPANNUNG DC 24 V
7VH1813
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 217) MELDEKREIS 2S GEBRUECKT AUSLOESEKREIS 2S NENNSPANNUNG DC 60 V
7VH600.-..A.0-.AA0
ANALOG SINGLE-PHASE HIGH IMPEDANCE DIFFERENT. RELAY BINARY INPUT VOLTAGE:24 TO 250V FOR RESET OF LOCKOUT PICKUP VOLTAGE SETTABLE VIA RESISTORS
7VH1603
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 216) MELDEKREIS 2S AUSLOESEKREIS 2S GEBRUECKT + 4S NENNSPANNUNG DC 60 V
7VH1605
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 216) MELDEKREIS 2S AUSLOESEKREIS 2S GEBRUECKT + 4S NENNSPANNUNG DC 125 V
7VH1644
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 216) MELDEKREIS 2S + 2S AUSLOESEKREIS 2S + 2S GEBRUECKT NENNSPANNUNG DC 110 V
7VH1615
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 216) MELDEKREIS 2S GEBRUECKT AUSLOESEKREIS 2S + 4S NENNSPANNUNG DC 125 V
7VH1645
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 216) MELDEKREIS 2S + 2S AUSLOESEKREIS 2S + 2S GEBRUECKT NENNSPANNUNG DC 125 V
7VH1706
DRUCKSCHALTER-RELAISKOMBINATION FLACHBAUGRUPPENAUSFUEHRUNG MELDEKREIS 2S AUSLOESEKREIS 2S GEBRUECKT + 4S NENNSPANNUNG DC 220 V
7VH1716
DRUCKSCHALTER-RELAISKOMBINATION FLACHBAUGRUPPENAUSFUEHRUNG MELDEKREIS 2S GEBRUECKT + 4S AUSLOESEKREIS 2S + 4S NENNSPANNUNG DC 220 V
7VH1642
DRUCKSCHALTER-RELAISKOMBINATION GEHAEUSEAUSF. (EUKAP NR. 216) MELDEKREIS 2S + 2S AUSLOESEKREIS 2S + 2S GEBRUECKT NENNSPANNUNG DC 48 V