Энергетика PTD / 8AA
8AA2040-0WC07-3A.0
SUPPLEMENTARY DEVICE SHORT-CIRCUIT INDICATOR FOR SWITCH DISCONNEC. PANEL 12KV GREAT PANEL DEPTH FOR BUSBAR INSTALLATION WITH MAKE-PROOF EARTHING SWITCH ROTOR SYSTEM (MECHAN.)
8AA2040-0WC12-0CC0
SUPPLEMENTARY DEVICE FUSE BOX FOR SECONDARY VOLTAGE TRANSFORMER PROTECTION FOR METERING PANEL 12KV GREAT PANEL DEPTH IN LV CUBICLE: SUPPLIED BY CUSTOMER
8AA2020-0UC.3-4...
FITTING OF VOLTAGE TRANSFORMER IN SWITCH-DISCONNECTOR PANEL GREAT PANEL DEPTH 7.2KV, SCHEME 34
8AA2020-4EA12
DRAW-OUT SECTION FOR VACUUM CIRCUIT-BREAKER 3AG WITH 24POLE PLUG CONNECTOR FOR SWITCH PANEL 7.2KV 1250A AUXILIARY SWITCH TO POSITION SIGNAL: WITH 2NO+2NC
8AA2020-0UC.4-1...
FITTING OF VOLTAGE TRANSFORMER IN METERING PANEL GREAT PANEL DEPTH 7.2KV, SCHEME 41
8AA2020-0UC.4-2...
FITTING OF VOLTAGE TRANSFORMER IN METERING PANEL GREAT PANEL DEPTH 7.2KV, SCHEME 42
8AA2020-4EA21
DRAW-OUT SECTION FOR VACUUM CIRCUIT-BREAKER 3AG WITH 64POLE PLUG CONNECTOR FOR SWITCH PANEL 7.2KV 1250A AUXILIARY SWITCH TO POSITION SIGNAL: WITH 1NO+1NC
8AA2020-0UC.4-3...
FITTING OF VOLTAGE TRANSFORMER IN METERING PANEL GREAT PANEL DEPTH 7.2KV, SCHEME 43
8AA2020-4EA22
DRAW-OUT SECTION FOR VACUUM CIRCUIT-BREAKER 3AG WITH 64POLE PLUG CONNECTOR FOR SWITCH PANEL 7.2KV 1250A AUXILIARY SWITCH TO POSITION SIGNAL: WITH 2NO+2NC
8AA2020-0UC.4-4...
FITTING OF VOLTAGE TRANSFORMER IN METERING PANEL GREAT PANEL DEPTH 7.2KV, SCHEME 44
8AA2020-4EB10
DRAW-OUT SECTION FOR VACUUM CIRCUIT-BREAKER 3AH WITH 24POLE PLUG CONNECTOR FOR SWITCH PANEL 7.2KV 1250A AUXILIARY SWITCH TO POSITION SIGNAL: WITHOUT
8AA2020-0UD.2-4...
FITTING OF VOLTAGE TRANSFORMER IN SWITCH-DISCONNECTOR PANEL SMALL PANEL DEPTH 7.2KV, SCHEME 24
8AA2040-0JC.4-1.A.
FITTING OF CURRENT TRANSFORMER/ SUPPORT IN METERING PANEL GREAT PANEL DEPTH 12KV, SCHEME 41
8AA2040-0WD07-3B.0
SUPPLEMENTARY DEVICE SHORT CIRCUIT INDICATOR FOR SWITCH DISCONNECT. PANEL 12KV SMALL PANEL DEPTH FOR BUSBAR INSTALLATION WITH MAKE-PROOF EARTHING SWITCH LIQUID-COOLED SYSTEM
8AA2040-0JC.4-2.A.
FITTING OF CURRENT TRANSFORMER/ SUPPORT IN METERING PANEL GREAT PANEL DEPTH 12KV, SCHEME 42
8AA2041-2D..5-2..1
NARROW PANEL, SMALL PANEL DEPTH 12KV 16KA/1S 630A WITH CABLE CONNECTION, RIGHT FOR FITTING OF DEVICES ACC. TO SCHEME 52
8AA2041-2C..2-2..0
SWITCH DISCONNECTOR PANEL GREAT PANEL DEPTH 12KV 16KA/1S 630A WITH CABLE CONNECTION FOR FITTING OF DEVICES ACC. TO SCHEME 22
8AA2041-2D..5-2..2
NARROW PANEL, SMALL PANEL DEPTH 12KV 16KA/1S 630A WITH CABLE CONNECTION, LEFT FOR FITTING OF DEVICES ACC. TO SCHEME 52
8AA2041-2C..2-3..0
SWITCH DISCONNECTOR PANEL GREAT PANEL DEPTH 12KV 16KA/1S 630A WITH CABLE CONNECTION FOR FITTING OF DEVICES ACC. TO SCHEME 23
8AA2041-2S..2-2...
SPECIAL SWITCH DISC.PANEL 12KV 16KA/1S 630A FOR FITTING OF DEVICES ACC.TO SCHEME 22
8AA2041-2C..2-5..2
SWITCH DISCONNECTOR PANEL GREAT PANEL DEPTH 12KV 16KA/1S 630A AS BYPASS, ON THE LEFT FOR FITTING OF DEVICES ACC. TO SCHEME 25
8AA2041-2S..2-3...
SPECIAL SWITCH DISC.PANEL 12KV 16KA/1S 630A FOR FITTING OF DEVICES ACC.TO SCHEME 23
8AA2041-2C..2-6..1
SWITCH DISCONNECTOR PANEL GREAT PANEL DEPTH 12KV 16KA/1S 630A AS BYPASS, ON THE RIGHT FOR FITTING OF DEVICES ACC. TO SCHEME 26
8AA2060-0JC.2-5.A.
FITTING OF CURRENT TRANSFORMER/ SUPPORT IN SWITCH-DISCONNECTOR PANEL, GREAT PANEL DEPTH 17.5KV, SCHEME 25
8AA2060-0WC06-0H.0
SUPPLEMENTARY DEVICE EARTHING STUD FOR SWITCH DISCONNECTOR PANEL 17.5KV GREAT PANEL DEPTH FITTING AT CONNECTION BELOW FOR SCHEMES 23, 24, 27
8AA2060-0JC.3-1.A.
FITTING OF CURRENT TRANSFORMER/ SUPPORT IN METERING PANEL GREAT PANEL DEPTH 17.5KV, SCHEME 31
8AA2060-0WC06-0K.0
SUPPLEMENTARY DEVICE EARTHING STUD FOR SWITCH DISCONNECTOR PANEL 17.5KV GREAT PANEL DEPTH FITTING AT CONNECTION BELOW FOR SCHEMES 31 TO 34, 41 TO 45
8AA2060-0JC.3-2.A.
FITTING OF CURRENT TRANSFORMER/ SUPPORT IN METERING PANEL GREAT PANEL DEPTH 17.5KV, SCHEME 32
8AA2060-0WC07-1D.0
SUPPLEMENTARY DEVICE SHORT-CIRCUIT INDICATOR FOR SWITCH DISCONNEC. PANEL 17.5KV GREAT PANEL DEPTH FOR CABLE INSTALLATION MAUEL RESET, TYPE ALPHA M W/O REMOTE CONTACT CONTROL
8AA2060-0JC.3-3.A.
FITTING OF CURRENT TRANSFORMER/ SUPPORT IN METERING PANEL GREAT PANEL DEPTH 17.5KV, SCHEME 33
8AA2060-0JC.3-4.A.
FITTING OF CURRENT TRANSFORMER/ SUPPORT IN METERING PANEL GREAT PANEL DEPTH 17.5KV, SCHEME 34
8AA2060-0WC07-1F.0
SUPPLEMENTARY DEVICE SHORT-CIRCUIT INDICATOR FOR SWITCH DISCONNEC. PANEL 17.5KV GREAT PANEL DEPTH FOR CABLE INSTALLATION AUTOMATIC RESET AFTER 2 HOURS TYPE ALPHA E W/O REMOTE CONTACT CONTROL
8AA2060-0JC.4-2.A.
FITTING OF CURRENT TRANSFORMER/ SUPPORT IN METERING PANEL GREAT PANEL DEPTH 17.5KV, SCHEME 42
8AA2060-0PC02-4BA0
ADDITIONAL FITTING IN THE PRIMARY CIRCUIT OF SWITCH DISCONNECTOR PANEL/ METERING PANEL 17.5KV GREAT PANEL DEPTH: 3 SURGE ARRESTERS (W/O WIRING) FOR SCHEME 24
8AA2060-0WD07-3B.0
SUPPLEMENTARY DEVICE SHORT CIRCUIT INDICATOR FOR SWITCH DISCONNECT. PANEL 17.5KV SMALL PANEL DEPTH FOR BUSBAR INSTALLATION WITH MAKE-PROOF EARTHING SWITCH LIQUID-COOLED SYSTEM
8AA2060-0PC03-3EA0
ADDITIONAL FITTING IN THE PRIMARY CIRCUIT OF SWITCH DISCONNECTOR PANEL/ METERING PANEL 17.5KV GREAT PANEL DEPTH: FAULT INITIATING SWITCH 3DG30 W/O WIRING FOR SCHEME 33
8AA2060-0WD11-0BA0
SUPPLEMENTARY DEVICE COUPLING DEVICE MOUNTING SET FOR CAPACITY VOLTAGE DISPLAY SWITCH DISCONNECT. PANEL 17.5KV SMALL PANEL DEPTH AT SCHEMES 21 TO 27 INSTALLATION PLACE: ON BUSBAR
8AA2060-0PC03-4EA0
ADDITIONAL FITTING IN THE PRIMARY CIRCUIT OF SWITCH DISCONNECTOR PANEL/ METERING PANEL 17.5KV GREAT PANEL DEPTH: FAULT INITIATING SWITCH 3DG30 W/O WIRING FOR SCHEME 34
8AA2060-0WD11-0DA0
SUPPLEMENTARY DEVICE COUPLING DEVICE MOUNTING SET FOR CAPACITY VOLTAGE DISPLAY SWITCH DISCONNECT. PANEL 17.5KV SMALL PANEL DEPTH AT SCHEMES 21 TO 27 INSTALLATION PLACE: AT CONNECTION BELOW
8AA2060-0PD02-1BA0
ADDITIONAL FITTING IN THE PRIMARY CIRCUIT OF SWITCH DISCONNECTOR PANEL/ METERING PANEL 17.5KV SMALL PANEL DEPTH: 3 SURGE ARRESTERS (W/O WIRING) FOR SCHEME 21
8AA2060-0PD02-2BA0
ADDITIONAL FITTING IN THE PRIMARY CIRCUIT OF SWITCH DISCONNECTOR PANEL/ METERING PANEL 17.5KV SMALL PANEL DEPTH: 3 SURGE ARRESTERS (W/O WIRING) FOR SCHEME 22
8AA2060-0WD12-0DC0
SUPPLEMENTARY DEVICE FUSE BOX FOR SECONDARY VOLTAGE TRANSFORMER PROTECTION IN METERING PANEL 17.5KV SMALL PANEL DEPTH IN SUPPORTING CROSS-RACK: SUPPLIED BY CUSTOMER
8AA2060-0PD02-3BA0
ADDITIONAL FITTING IN THE PRIMARY CIRCUIT OF SWITCH DISCONNECTOR PANEL/ METERING PANEL 17.5KV SMALL PANEL DEPTH: 3 SURGE ARRESTERS (W/O WIRING) FOR SCHEME 23
8AA2060-0PD02-4BA0
ADDITIONAL FITTING IN THE PRIMARY CIRCUIT OF SWITCH DISCONNECTOR PANEL/ METERING PANEL 17.5KV SMALL PANEL DEPTH: 3 SURGE ARRESTERS (W/O WIRING) FOR SCHEME 24
8AA2060-0PD03-3EA0
ADDITIONAL FITTING IN THE PRIMARY CIRCUIT OF SWITCH DISCONNECTOR PANEL/ METERING PANEL 17.5KV SMALL PANEL DEPTH: FAULT INITIATING SWITCH 3DG30 W/O WIRING FOR SCHEME 33
8AA2060-0XA05-0DA0
PLANT MODULE FOR SWITCH PANEL 17.5KV GREAT PANEL DEPTH END WALL AT LEFT
8AA2060-0PD03-4EA0
ADDITIONAL FITTING IN THE PRIMARY CIRCUIT OF SWITCH DISCONNECTOR PANEL/ METERING PANEL 17.5KV SMALL PANEL DEPTH: FAULT INITIATING SWITCH 3DG30 W/O WIRING FOR SCHEME 34
8AA2060-0UB.1-1.A1
VOLTAGE TRANSFORMER FITTING IN CIRCUIT-BREAKER PANEL SECONDARY WIRING IN LV-CUBICLE 17.5KV, SCHEME 11
8AA2060-0XA05-0FA0
PLANT MODULE FOR SWITCH PANEL 17.5KV PARTITION/END WALL FOR COMBINATION OF SMALL AND GREAT PANEL DEPTH