Энергетика PTD / 8AX
8AX2004
EARTHING ACCESSORIES WITH BUTTERFLY BOLT M12 INCL. EARTHING BAR FOR T-BOLT, 70SQMM
8AX1052
THROW-OVER RELAY (SSP 43-119) F. PRESSURE SWITCH SYSTEM 8AX10 OPERATING VOLTAGE DC 24V
8AX1053
THROW-OVER RELAY (SSP 43-119) F. PRESSURE SWITCH SYSTEM 8AX10 OPERATING VOLTAGE DC 24V
8AX1054
THROW-OVER RELAY (SSP 43-119) F. PRESSURE SWITCH SYSTEM 8AX10 OPERATING VOLTAGE DC 60V
8AX1055
THROW-OVER RELAY (SSP 43-119) F. PRESSURE SWITCH SYSTEM 8AX10 OPERATING VOLTAGE DC 110V
8AX9101-3....
CUSTOMER TERMINAL: MOUNTED AND INSCRIPTED AND CONDUCTOR BETWEEN STANDARD TERMINAL AND CONDUCTOR TERMINAL CONDUCTOR 2.5 SQMM
8AX2206
OPERATING LEVER FOR SWITCH DISCONNECTOR AND MAKE-PROOF EARTH. SWITCH IN THE SWITCH DISC. PANEL
8AX2226
MANDATORY SINGS SET CONSISTING OF 1 X : SAFETY REGULATIONS FOR H.V. SWITCHGEAR, OPERATION OF POWER SYSTEMS, FIRE FIGHTING INSTRUCTIONS, FIRST AID INSTRUCTIONS FOR ACCIDENTS CAUSED BY ELECTRICAL CURRENT
8AX2207
TRIP-FREE OPERATING LEVER FOR MAKE-PROOF EARTH. SWITCH IN THE CIRCUIT-BREAKER PANEL
8AX2227
WARNING SIGNS SET CONSISTING OF 3 X CAUTION: EARTHED AND SHORTED, HIGH VOLTAGE !, CAUTION ! DANGER OF LIFE ! DO NOT OPERATE ! DANGER !
8AX2210
INSULATING PROTECTION BARRIER FOR SWITCH DISCONNECTOR PANEL UP TO 12KV, SMALL PANEL DEPTH
8AX2211
INSULATING PROTECTION-BARRIER FOR SWITCH DISCONNECTOR PANEL UP TO 12KV, GREAT PANEL DEPTH
8AX2213
INSULATING PROTECTION BARRIER FOR SPECIAL PANEL UP TO 12KV WITH SWITCH DISCONNECTOR AT BUSBAR
8AX9300-1...1
INSTALLATION UND WIRING OF A LOW-VOLTAGE DEVICE FOR SWITCHGEAR 8AA CURRENT CONDUCTION 2.5 SQMM OTHER CONDUCTION 1.5 SQMM SIEMENS STANDARD-CLAMP
8AX9300-3...6
INSTALLATION AND WIRING OF A LOW-VOLTAGE DEVICE FOR SWITCHGEAR 8DH, 8DJ, SIMOSEC CT.SECONDARY WIRING 2.5 SQMM CONTROL WIRING 2.5 SQMM (TYPE: FA. PHOENIX)
8AX9300-4...1
INSTALLATION UND WIRING OF A LOW-VOLTAGE DEVICE FOR SWITCHGEAR 8AA CURRENT CONDUCTION 4 SQMM OTHER CONDUCTION 2.5 SQMM SIEMENS STANDARD-CLAMP
8AX9300-2...1
INSTALLATION UND WIRING OF A LOW-VOLTAGE DEVICE FOR SWITCHGEAR 8AA CURRENT CONDUCTION 4 SQMM OTHER CONDUCTION 1,5 SQMM SIEMENS STANDARD-CLAMP
8AX9300-4...6
INSTALLATION AND WIRING OF A LOW-VOLTAGE DEVICE FOR SWITCHGEAR 8DH, 8DJ, SIMOSEC CT.SECONDARY WIRING 4 SQMM CONTROL WIRING 2.5 SQMM (TYPE: FA. PHOENIX)
8AX9300-2...6
INSTALLATION AND WIRING OF A LOW-VOLTAGE DEVICE FOR SWITCHGEAR 8DH, 8DJ, SIMOSEC CT.SECONDARY WIRING 4 SQMM CONTROL WIRING 1.5 SQMM (TYPE: FA. PHOENIX)
8AX9306-0AA00
THERMOSTAT 8AX9 TO HEATING CONTROL INCLUSIVE INSTALLATION AND WIRING IN SWITCHGEAR 8DH, 8AA, SIMOSEC
8AX9306-5...6
INSTALLATION AND WIRING OF A INPUT/OUTPUT DEVICE (6MD633) FOR SWITCHGEAR 8DH, 8AA, SIMOSEC
8AX9304-5...6
INSTALLATION AND WIRING OF INPUT/OUTPUT DEVICE (6MD631) OR A MULTIFUNKTION PROTCTIONUNIT (7SJ62) FOR SWITCHGEAR 8DH, 8AA, SIMOSEC
8AX9307-5...6
INSTALLATION AND WIRING OF AN INSTRUMENTATION AND CONTROL CENTRAL MODULE (6MD2000) FOR SWITCHGEAR 8DH, 8AA, SIMOSECRD) CT.WIRINGS 2.5 SQMM OTHER WIRINGS 1.0 SQMM (STANDARD) WITHOUT BUSCONNECTION
8AX9305-5...6
INSTALLATION AND WIRING OF A INPUT/OUTPUT DEVICE (6MD632/6MD634) FOR SWITCHGEAR 8DH, 8AA, SIMOSEC
8AX9308-5...6
INSTALLATION AND WIRING OF A FEEDER PROTECTION (7SA61,7SA63) MULTIFUNKTION PROTECTION(7SJ63) FOR SWITCHGEAR 8DH, 8AA, SIMOSEC OT.WIRINGS 2.5 SQMM OTHER WIRINGS 1.0 SQMM (STANDARD) WITHOUT BUSCONNECTION
8AX9401-1....
CUSTOMER TERMINAL: FOR SWITCHGEAR 8DH, 8AA, SIMOSEC MOUNTED AND INSCRIPTED AND CONDUCTOR BETWEEN STANDARD TERMINAL AND CONDUCTOR TERMINAL CONDUCTOR 1.0 SQMM
8AX9401-3....
CUSTOMER TERMINAL: FOR SWITCHGEAR 8DH, 8AA, SIMOSEC MOUNTED AND INSCRIPTED AND CONDUCTOR BETWEEN STANDARD TERMINAL AND CONDUCTOR TERMINAL CONDUCTOR 2.5 SQMM
8AX9426-0AA00
SPARE TERMINAL, FOR SWITCHGEAR 8DH, 8AA, SIMOSEC FITTED AND WITH INSCRIPTION THROUGH-TYPE TERMINAL (VOLTAGE) PHOENIX TERMINAL VBST4 OR SAME EDITION
8AX9405-0AA00
SPARE TERMINAL, FOR SWITCHGEAR 8DH, 8AA, SIMOSEC FITTED AND WITH INSCRIPTION INSTRUMENT ISOLATING TERMINAL (CURRENT) PHOENIX TERMINAL URTK/S UP TO 6 SQMM (STANDARD TYPE)
8AX9000-1...1
INSTALLATION UND WIRING OF A LOW-VOLTAGE DEVICE CURRENT CONDUCTION 2.5 SQMM OTHER CONDUCTION 1.5 SQMM SIEMENS STANDARD-CLAMP
8AX9000-3...6
INSTALLATION AND WIRING OF A LOW-VOLTAGE DEVICE CT.SECONDARY WIRING 2.5 SQMM CONTROL WIRING 2.5 SQMM
8AX9000-1...6
INSTALLATION AND WIRING OF A LOW-VOLTAGE DEVICE CT.SECONDARY WIRING 2.5 SQMM CONTROL WIRING 1.5 SQMM
8AX9000-4...1
INSTALLATION UND WIRING OF A LOW-VOLTAGE DEVICE CURRENT CONDUCTION 4 SQMM OTHER CONDUCTION 2.5 SQMM SIEMENS STANDARD-CLAMP
8AX9000-2...1
INSTALLATION UND WIRING OF A LOW-VOLTAGE DEVICE CURRENT CONDUCTION 4 SQMM OTHER CONDUCTION 1,5 SQMM SIEMENS STANDARD-CLAMP
8AX9000-4...6
INSTALLATION AND WIRING OF A LOW-VOLTAGE DEVICE CT.SECONDARY WIRING 4 SQMM CONTROL WIRING 2.5 SQMM
8AX9000-2...6
INSTALLATION AND WIRING OF A LOW-VOLTAGE DEVICE CT.SECONDARY WIRING 4 SQMM CONTROL WIRING 1.5 SQMM
8AX9000-5...1
INSTALLATION UND WIRING OF A LOW-VOLTAGE DEVICE CURRENT CONDUCTION 2.5 SQMM OTHER CONDUCTION 1 SQMM SIEMENS STANDARD-CLAMP
8AX9000-3...1
INSTALLATION UND WIRING OF A LOW-VOLTAGE DEVICE CURRENT CONDUCTION 2.5 SQMM OTHER CONDUCTION 2.5 SQMM SIEMENS STANDARD-CLAMP
8AX9000-5...6
INSTALLATION AND WIRING OF A LOW-VOLTAGE DEVICE CT.WIRINGS 2.5 SQMM OTHER WIRINGS 1.0 SQMM (STANDARD)
8AX9001-5BB16
INSTALLATION AND WIRING OF A PRESSURE SWITCH IN SWITCH PANELS 8BC1 AND 8BD1 INCL.PRESSURE SWITCH D845
8AX9006-0AA00
THERMOSTAT TO HEATING CONTROL INCLUSIVE INSTALLATION AND WIRING IN SWITCHBOARDS 8BJ AND 8BK
8AX9006-5...6
INSTALLATION AND WIRING OF A INPUT/OUTPUT DEVICE 6MB5220-0 (EAG 221) CT.WIRINGS 2.5 SQMM OTHER WIRINGS 1.0 SQMM (STANDARD)