Приводная техника / 2GA
2GA3341-4B
EXPERIMENTAL PANEL, H=297MM TWO POLE ON/OFF SWITCH SWITCH POSITIONS: O-I-O-I, 16A/380V AC/220V DC
2GA3341-4C
EXPERIMENTAL PANEL, H=297MM ON/OFF SWITCH, 2-POLE, SWITCH POSITIONS 0-I-0-I, 40A/500V AC/ 440V DC
2GA3311-4A
EXPERIMENTAL PANEL, H=297MM 3 DIAZED FUSE ELEMENTS,16A/ 380V AC/250V DC WITH FUSE PLUGS FOR 4/6/10A
2GA3317-4A
EXPERIMENTAL PANEL, H=297MM POLE-CHANGING SWITCH 16A/500V AC, FOR 2-SPEED DAHLANDER CIRCUIT
2GA3317-4B
EXPERIMENTAL PANEL, H=297MM POLE-CHANGING SWITCH, 32A/500V AC, FOR 2-SPEED DAHLANDER CIRCUIT
2GA3348-4A
EXPERIMENTAL PANEL, H=297MM SINGLE-PHASE TRANSFORMER 250VA, WITH SEPARATE WINDINGS
2GA3348-4B
EXPERIMENTAL PANEL, H=297MM SINGLE PHASE TRANSFORMER 100VA WITH SEPARATE WINDINGS
2GA3318-4A
EXPERIMENTAL PANEL, H=297MM, POLE-CHANGING SWITCH 16A/ 500V AC, 2 SPEEDS, 2 SEPARATE WINDINGS
2GA3350-4A
EXPERIMENTIERPLATTE, H=297MM DREHSTROM-TRANSFORMATOR 300VA MIT GETRENNTEN WICKLUNGEN
2GA3350-4B
EXPERIMENTAL PANEL 3-PHASE TRANSFORMER WITH SEPARATE WINDINGS 380V / 220V VECTOR GROUP DYN 5
2GA3320-4A
EXPERIMENTIERPLATTE, H=297MM POLUMSCHALTER 16A/500V AC, 3 DREHZAHLEN, 2 GETRENNTE WICKLUNGEN
2GA3321-4T
EXPERIMENTAL PANEL WITH FOUR 3-POLE CONTACTOR, AC 4A/400 V 2 MAKE AND 2 BREAK CONTACTS OPERATING VOLTAGE DC 24 V
2GA3321-4D
EXPERIMENTAL PANEL, H=297MM 3-POLE CONTACTER, 45A/500V AC, AUXILIARY SWITCH WITH 2 MAKE+ 2 BREAK CONTACTS, OPERATING VOLTAGE 220V/50 HZ
2GA3321-4U
SICONTROL TRAINING UNIT CONTROL MODULE WITH 4 INPUTS WIRED ON 2MM SOCKETS AND 2 RELAY OUTPUTS WIRED ON 4MM SAFETY SOCKETS INCLUDING MAINS SUPPLY CABLE
2GA3321-4E
EXPERIMENTAL PANEL, H=297MM 3-POLE CONTACTER, 63A/500V AC, AUXILIARY SWITCH WITH 2 MAKE+ 2 BREAK CONTACTS, OPERATING VOLTAGE 220V/50 HZ
2GA3360-1E
COMPACT BRAKING UNIT WITH ANALOG SPEED AND TORQUE INDICATION, 200W-RANGE AC 50HZ/220V MAXIMUM BRAKING TORQUE 4MM
2GA3360-1F
EDDY-CURRENT BRAKE 200 W BREADING POWER AT: 1500 RPM: 200 W 3000 RPM: 300 W EXCITATION VOLTAGE: 0-180 V DC
2GA3360-1G
DC DYNAMOMETER WITH ELECTRONIC TORQUE LOAD CELL (STRAIN GAUGE), BRAKING POWER 320W
2GA3360-5B
DC COMPOUND-WOUND MACHINE, 1350 MIN-1 GENERATOR OPERATION: 0.16KW/ 130V MOTOR OPERATION: 0.18KW/220V
2GA3360-1H
DC-DYNAMOMETER, 200 W 1500 RPM MOTOR OPERAT.: 0.4 KW/150V/3.4A GENERATOR OPERAT.: 0.4 KW/150 V 2.5 A, WITH MOUNTING FRAME
2GA3360-5C
DC SHUNT-WOUND MACHINE, 1350 MIN-1 GENERATOR OPERATION: 0.18KW/ 150V MOTOR OPERATION: 0.2KW/220V
2GA3360-1N
DREHZAHL-MESSEINRICHTUNG 200W-PROGR., MESSBEREICH 100 BIS 4000 MIN-1, 220V/50HZ
2GA3360-5E
DC SHUNT-WOUND MACHINE WITH TACHOGENERATOR GENERATOR OPERATION: 0.18KW/ 150V/1.2A MOTOR OPERATION: 0.2KW/220V/ 1.2A/1350 MIN-1
2GA3360-1P
CONTROL UNIT FOR EDDY-CURRENT BRAKE, 220W, WITH SPEED AND TORQUE MEASURE- MENT
2GA2772-2K
ELABO-INFORM ROLL-CONTAINER 420 X 820 X 675MM (W X D X H) CONSISTING OF 5 DRAWERS
2GA2734-0Q
PLUG-IN MODULE SYSTEM 266 DC STABILIZER WITH ANALOG DISPLAYS 2X0 TO 30V/1A, FIXED VOLTAGE 5V/3A
2GA2734-4P
PLUG-IN MODULE SYSTEM 266 DC STABILIZER WITH DIGITAL DISPLAY 0 TO 30V/1A, FIXED VOLTAGE 5V/3A
2GA2734-0T
PLUG-IN MODULE SYSTEM 266 DC STABILIZER 2X 0 TO 30V/4A AND FIXED VOLTAGE 5V/3A WITH ANALOG DISPLAYS
2GA2734-4R
PLUG-IN MODULE SYSTEM 266 DC STABILIZER WITH DIGITAL DISPLAY 0 TO 60V/1A, FIXED VOLTAGE 5V/3A
2GA2734-0U
PLUG-IN MODULE SYSTEM 266 DC STABILIZER WITH ANALOG DISPLAYS 2X0 TO 30V/2A, FIXED VOLTAGE 5V/3A
2GA2735-0K
PLUG-IN MODULE SYSTEM 266 AC/DC SUPPLY MODULE 0 TO 220V(250V) 3A AND 0 TO 44V(50V) 10A, FLOATING
2GA2734-4S
PLUG-IN MODULE SYSTEM 266 DC STABILIZER WITH DIGITAL DISPLAYS 2X0 TO 30V/1A, TWO ROWS OF BUTTONS PERMIT EACH OUTPUT TO BE SWITCHED OVER TO FIXED VOLTAGES OF 5,12,15V