Энергетика PTD / 3AJ
3AJ9452-.....-5...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM, EARTHING SWITCH IN CONNECTION COMPARTMENT AN ON BUSBAR, WITH MANUAL OPERATING MECHANISM DC 48V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT
3AJ9452-.....-7...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM, EARTHING SWITCH IN CONNECTION COMPARTMENT AN ON BUSBAR, WITH MANUAL OPERATING MECHANISM DC 48V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT AND EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT (OPTION)
3AJ9455-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM, EARTHING SWITCH IN CONNECTION COMPARTMENT AN ON BUSBAR, WITH MANUAL OPERATING MECHANISM DC 220V, INCL. VARISTOR CIRCUITRY
3AJ9455-.....-6...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM, EARTHING SWITCH IN CONNECTION COMPARTMENT AN ON BUSBAR, WITH MANUAL OPERATING MECHANISM DC 220V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT
3AJ9455-.....-7...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM, EARTHING SWITCH IN CONNECTION COMPARTMENT AN ON BUSBAR, WITH MANUAL OPERATING MECHANISM DC 220V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT AND EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT (OPTION)
3AJ9426-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AC 100V
3AJ9456-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT AND ON BUSBAR WITH MOTOR OPERATING MECHANISM AC 100V
3AJ9427-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AC 110V
3AJ9457-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT AND ON BUSBAR WITH MOTOR OPERATING MECHANISM AC 110V
3AJ9428-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AC 230V
3AJ9440-.....-7...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT AND EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT (OPTION)
3AJ9472-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 48V, INCL. VARISTOR CIRCUITRY
3AJ9472-.....-6...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 48V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT
3AJ9444-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AND EARTHING SWITCH IN CONNECTION COMPARTMENT DC 110V, INCL. VARISTOR CIRCUITRY
3AJ9444-.....-5...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AND EARTHING SWITCH IN CONNECTION COMPARTMENT DC 110V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT
3AJ9476-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM AC 100V
3AJ9445-.....-5...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AND EARTHING SWITCH IN CONNECTION COMPARTMENT DC 220V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT
3AJ9477-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM AC 110V
3AJ9446-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MOTOR OPERATING MECHANISM AC 100V
3AJ9478-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM AC 230V
3AJ9447-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 275MM PFWV 50KV; 50 X ISC 25KA; 2500A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MOTOR OPERATING MECHANISM AC 110V
3AJ5800-.....-0...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHOUT WITHDRAWABLE PART AND EARTHING SWITCH
3AJ5800-.....-3...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHOUT WITHDRAWABLE PART AND EARTHING SWITCH ELECTROMAGNETIC FOR WITHDRAWABLE PART, EARTHING SWITCH IN CONNECTION COMPARTMENT AND IN BUSBAR ADDITIONAL COMPARTMENT
3AJ5800-.....-1...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHOUT WITHDRAWABLE PART AND EARTHING SWITCH ELECTROMAGNETIC FOR WITHDRAWABLE PART
3AJ5800-.....-4...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHOUT WITHDRAWABLE PART AND EARTHING SWITCH ELECTROMAGNETIC FOR WITHDRAWABLE PART, EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT
3AJ5800-.....-2...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHOUT WITHDRAWABLE PART AND EARTHING SWITCH ELECTROMAGNETIC FOR WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT
3AJ5848-.....-0...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MOTOR OPERATING MECHANISM AC 230V
3AJ5820-.....-0...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHDRAWABLE PART WITH MANUAL OPERATING MECHANISM
3AJ5820-.....-4...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHDRAWABLE PART WITH MANUAL OPERATING MECHANISM ELECTROMAGNETIC FOR WITHDRAWABLE PART, EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT
3AJ5820-.....-1...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHDRAWABLE PART WITH MANUAL OPERATING MECHANISM ELECTROMAGNETIC FOR WITHDRAWABLE PART
3AJ9365-.....-6...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM WITHOUT EARTHING SWITCH IN CONNECTION COMPARTMENT, EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 220V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT
3AJ9340-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 25KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM
3AJ5865-.....-0...
VACUUM CIRCUIT-BREAKER NXACT DISCONNECTOR MODULE NXAIR 12KV;POLE-CENTRE DISTANCE 210MM PFWV 42KV; 25KA; 2500A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM WITHOUT EARTHING SWITCH IN CONNECTION COMPARTMENT, EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 220V, INCL. VARISTOR CIRCUITRY
3AJ8940-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM
3AJ8940-.....-1...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM ELECTROMAGNETIC FOR WITHDRAWABLE PART
3AJ8940-.....-5...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT
3AJ8940-.....-2...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM ELECTROMAGNETIC FOR WITHDRAWABLE PART AND EARTHING SWITCH IN CONNECTION COMPARTMENT
3AJ8940-.....-6...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM ELECTROMAGNETIC FOR EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT
3AJ8940-.....-3...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM ELECTROMAGNETIC FOR WITHDRAWABLE PART EARTHING SWITCH IN CONNECTION COMPARTMENT AND IN BUSBAR ADDITIONAL COMPARTMENT
3AJ8940-.....-7...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART AND EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT AND EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT (OPTION)
3AJ8972-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 48V, INCL. VARISTOR CIRCUITRY
3AJ8972-.....-6...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 48V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT
3AJ8941-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AND EARTHING SWITCH IN CONNECTION COMPARTMENT DC 24V, INCL. VARISTOR CIRCUITRY
3AJ8941-.....-5...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AND EARTHING SWITCH IN CONNECTION COMPARTMENT DC 24V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT
3AJ8973-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 60V, INCL. VARISTOR CIRCUITRY
3AJ8973-.....-6...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 60V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT
3AJ8942-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AND EARTHING SWITCH IN CONNECTION COMPARTMENT DC 48V, INCL. VARISTOR CIRCUITRY
3AJ8942-.....-5...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM AND EARTHING SWITCH IN CONNECTION COMPARTMENT DC 48V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN CONNECTION COMPARTMENT
3AJ8974-.....-0...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 110V, INCL. VARISTOR CIRCUITRY
3AJ8974-.....-6...
BREAKER-MODULE FOR NXAIR M CIRCUIT-BREAKER MODULE 24KV POLE-CENTRE DISTANCE 210MM PFWV 50KV; 50 X ISC 16KA; 1250A WITHDRAWABLE PART WITH MOTOR OPERATING MECHANISM EARTHING SWITCH IN CONNECTION COMPARTMENT WITH MOTOR OPERATING MECHANISM EARTHING SWITCH ON BUSBAR WITH MANUAL OPERATING MECHANISM DC 110V, INCL. VARISTOR CIRCUITRY ELECTROMAGNETIC FOR EARTHING SWITCH IN BUSBAR ADDITIONAL COMPARTMENT