3WN1531-1H...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 3-POLE; SIZE II IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL SETTING RANGE 640-1600A
3WN5343-1G...-....
FIXED-MOUNTED CIRCUIT-BREAKER 4-POLE, SIZE I IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V VERTICAL BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 500 TO 1250A
3WN5343-2G...-....
FIXED-MOUNTED CIRCUIT-BREAKER 4-POLE, SIZE I IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V VERTICAL BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 500 TO 1250A W.MOUNTED ARC-CHUTE EXTENSION
3WN5343-1W...-....
FIXED-MOUNTED ISOLATING CIRCUIT-BREAKER 4-POLE, SIZE I IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V VERTICAL BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM
3WN5371-1E...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, 50KA SIZE I/2, RTD.CONT.CURR.1250A CURR.TRANSFORM.RATED CURR.800A SETTING RANGE 320 TO 800A
3WN5371-1C...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, 50KA SIZE I/2, RTD.CONT.CURR.1250A CURR.TRANSFORM.RATED CURR.500A SETTING RANGE 200 TO 500A
3WN5371-2C...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, 50KA SIZE I/2, RTD.CONT.CURR.1250A CURR.TRANSFORM.RATED CURR.500A SETTING RANGE 200 TO 500A W.MOUNTED ARC-CHUTE EXTENSION
3WN5371-2W...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, 50KA SIZE I/2,RATD.CONTIN.CURR.1250A W.MOUNTED ARC-CHUTE EXTENSION
3WN5351-1C...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 200 TO 500A
3WN5351-2C...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 200 TO 500A W.MOUNTED ARC-CHUTE EXTENSION
3WN5351-1D...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 252 TO 630A
3WN5351-1E...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 320 TO 800A
3WN5351-2E...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 320 TO 800A W.MOUNTED ARC-CHUTE EXTENSION
3WN1571-1G...-....
WITHDRAWABLE CIRCUIT BREAKER 3-POLE; 80KA SIZE II, IN=2000A TRANSFORMER RATED CURRENT 1250A SETTING RANGE 500-1250A SETTING RANGE 500 TO 1250A
3WN1571-5G...-....
WITHDRAWABLE CIRCUIT BREAKER 3-POLE, TO AC 1000V SIZE II, IN=2000A TRANSFORMER RATED CURRENT 1250A SETTING RANGE 500-1250A
3WN1571-1H...-....
WITHDRAWABLE CIRCUIT BREAKER 3-POLE; 80KA SIZE II, IN=2000A TRANSFORMER RATED CURRENT 1600A SETTING RANGE 640-1600A SETTING RANGE 640 TO 1600A
3WN1571-5H...-....
WITHDRAWABLE CIRCUIT BREAKER 3-POLE, TO AC 1000V SIZE II, IN=2000A TRANSFORMER RATED CURRENT 1600A SETTING RANGE 640-1600A
3WN1571-5J...-....
WITHDRAWABLE CIRCUIT BREAKER 3-POLE, TO AC 1000V SIZE II, IN=2000A TRANSFORMER RATED CURRENT 2000A SETTING RANGE 800-2000A
3WN1571-5W...-....
WITHDRAWABLE LOAD INTERRUPTER SWITCH 3-POLE, TO AC 1000V SIZE II, IN=2000A
3WN1545-2L...-....
NON-WITHDRAW. CIRCUIT-BREAKER 3-POLE, SIZE II IN=2500A UP TO UE=600V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1545-5L...-....
NON-WITHDRAW. CIRCUIT-BREAKER 3-POLE, SIZE II IN=2500A UP TO UE=1000V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1545-2W...-....
NON-WITHDR. LOAD INTER. SWITCH 3-POLE, SIZE II IN=2500A UP TO UE=600V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL
3WN1545-5W...-....
NON-WITHDR. LOAD INTER. SWITCH 3-POLE, SIZE II IN=2500A UP TO UE=1000V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL
3WN1573-1H...-....
WITHDRAWABLE CIRCUIT BREAKER 4-POLE; 80KA TO AC 500V SIZE II, IN=2000A TRANSFORMER RATED CURRENT 1600A SETTING RANGE 640-1600A
3WN1573-2H...-....
WITHDRAWABLE CIRCUIT BREAKER 4-POLE, 80KA TO AC 500V SIZE II, IN=2000A TRANSFORMER RATED CURRENT 1600A SETTING RANGE 640-1600A WITH MOUNTED ARC-CHUTE EXTENSION
3WN1573-2J...-....
WITHDRAWABLE CIRCUIT BREAKER 4-POLE, 80KA TO AC 500V SIZE II, IN=2000A TRANSFORMER RATED CURRENT 2000A SETTING RANGE 800-2000A WITH MOUNTED ARC-CHUTE EXTENSION
3WN1573-2W...-....
WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE, 80KA TO AC 500V BAUGR.II, IN=2000A WITH MOUNTED ARC-CHUTE EXTENSION
3WN6071-0WA..-....
WITHDRAW. NON-AUT. CIRCUIT-B. 3-POLE, SIZE I IN=630A TO 690V, AC50/60HZ ICU=65KA AT 500V WITH READY-TO-CLOSE SIGNALLING SWITCH
3WN1551-2J...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 3-POLE, SIZE II IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 800-2000A WITH MOUNTED ARC-CHUTE EXTENSION EXTENSION
3WN1551-1H...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 3-POLE; SIZE II IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 640-1600A
3WN6083-0WA..-....
WITHDRAW. NON-AUT. CIRCUIT-B. 4-POLE, SIZE I IN=630A TO 690V, AC50/60HZ ICU=65KA AT 500V WITH READY-TO-CLOSE SIGNALLING SWITCH WITH GUIDE FRAME
3WN1551-1J...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 3-POLE; SIZE II IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 800-2000A
3WN1551-5G...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 3-POLE, SIZE II IN=2000A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 500-1250A
3WN1551-1W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 3-POLE; SIZE II IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL
3WN1551-5H...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 3-POLE, SIZE II IN=2000A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 640-1600A
3WN1551-2G...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 3-POLE, SIZE II IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 500-1250A WITH MOUNTED ARC-CHUTE EXTENSION
3WN1551-5J...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 3-POLE, SIZE II IN=2000A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 800-2000A
3WN1655-2L...-....
NON-WITHDRAW. CIRCUIT-BREAKER 3-POLE, SIZE II IN=3200A UP TO UE=600V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1551-5W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 3-POLE, SIZE II IN=2000A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL
3WN1575-2L...-....
WITHDRAWABLE CIRCUIT-BREAKER 3-POLE, SIZE II IN=2500A UP TO UE=600V DC
3WN1575-2W...-....
WITHDRAWABLE LOAD INTER. SWITCH 3-POLE, SIZE II IN=2500A UP TO UE=600V DC
3WN1575-5W...-....
WITHDRAWABLE LOAD INTER. SWITCH 3-POLE, SIZE II IN=2500A UP TO UE=1000V DC
3WN1553-2H...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE II /1 IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 640-1600A WITH MOUNTED ARC-CHUTE EXTENSION EXTENSION
3WN1553-1J...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE; SIZE II /1 IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 800-2000A
3WN1771-0H...-....
DRAW-OUT CIRCUIT-BREAKER SIZE III, RTD.CONT.CURR.3150A CURRENT TRANSFORMER RATED PRIMARY CURRENT 1600A
3WN1553-2J...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE II /1 IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 800-2000A WITH MOUNTED ARC-CHUTE EXTENSION EXTENSION
3WN1553-1W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE; SIZE II /1 IN=2000A TO UE=690 V AC50/60HZ ICU=80 KA AT 500 V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL
3WN1553-2W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE, SIZE II /1 IN=2000A TO UE=690 V AC50/60HZ ICU=80 KA AT 500 V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL WITH MOUNTED ARC-CHUTE EXTENSION
3WN60.1-0WA..-....
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE I IN=630A TO 690V, AC50/60HZ ICU=65KA AT 500V WITH READY-TO-CLOSE SIGNALLING SWITCH