Автоматизация / 3WN
3WN1041-2A...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/1 IN=630A TO UE=690V 50/60 HZ ICU=80KA AT 500V VERTICAL BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 126 TO 315A W.MOUNTED ARC-CHUTE EXTENSION
3WN1041-5D...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/1 IN=630A TO UE=690V 50/60 HZ ICU=25KA AT 1000V VERTICAL BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 252 TO 315A
3WN1041-2B...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/1 IN=630A TO UE=690V 50/60 HZ ICU=80KA AT 500V VERTICAL BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 160 TO 400A W.MOUNTED ARC-CHUTE EXTENSION
3WN1135-2W...-....
NON-WITHDR. LOAD INTER. SWITCH 3-POLE, SIZE I IN=1000A UP TO UE=600V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1041-5W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 3-POLE, SIZE I /1 IN=630A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL
3WN1067-5L...-....
NON-WITHDRAW. CIRCUIT-BREAKER 4-POLE, SIZE I IN=800A UP TO UE=1000V DC CONNECTION TOP HORIZONTAL CONNECTION BOTTOM HORIZONTAL
3WN1067-5W...-....
NON-WITHDR. LOAD INTER. SWITCH 4-POLE, SIZE I IN=800A UP TO UE=1000V DC CONNECTION TOP HORIZONTAL CONNECTION BOTTOM HORIZONTAL
3WN1045-2W...-....
NON-WITHDR. LOAD INTER. SWITCH 3-POLE, SIZE I IN=800A UP TO UE=600V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL
3WN1045-5W...-....
NON-WITHDR. LOAD INTER. SWITCH 3-POLE, SIZE I IN=800A UP TO UE=1000V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL
3WN1071-0A...-....
DRAW-OUT CIRCUIT-BREAKER SIZE I/1, RTD.CONT.CURR.630A CURRENT TRANSFORMER RATED PRIMARY CURRENT 315A
3WN1071-1B...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE; 80KA SIZE I/1, RTD.CONT.CURR.630A CURR.TRANSFORM.RATED CURR.400A SETTING RANGE 160 TO 400A
3WN1071-5B...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, UP TO 1000V SIZE I/1, RTD.CONT.CURR.630A CURR.TRANSFORM.RATED CURR.400A SETTING RANGE 160 TO 400A
3WN1071-5A...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, UP TO 1000V SIZE I/1, RTD.CONT.CURR.630A CURR.TRANSFORM.RATED CURR.315A SETTING RANGE 126 TO 315A
3WN1047-2L...-....
NON-WITHDRAW. CIRCUIT-BREAKER 4-POLE, SIZE I IN=800A UP TO UE=600V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1051-5A...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/1 IN=630A TO UE=1000V 50/60 HZ ICU=25KA AT 1000V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 126 TO 315A
3WN1051-5C...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/1 IN=630A TO UE=1000V 50/60 HZ ICU=25KA AT 1000V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 200 TO 500A
3WN5331-1C...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V VERTICAL BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 200 TO 500A
3WN5331-2G...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V VERTICAL BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 500 TO 1250A W.MOUNTED ARC-CHUTE EXTENSION
3WN5353-1G...-....
FIXED-MOUNTED CIRCUIT-BREAKER 4-POLE, SIZE I IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 500 TO 1250A
3WN5353-2W...-....
FIXED-MOUNTED ISOLATING CIRCUIT-BREAKER 4-POLE, SIZE I IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM W.MOUNTED ARC-CHUTE EXTENSION
3WN5361-2G...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 500 TO 1250A W.MOUNTED ARC-CHUTE EXTENSION
3WN5341-2G...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V VERTICAL BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 500 TO 1250A W.MOUNTED ARC-CHUTE EXTENSION
3WN5341-2W...-....
FIXED-MOUNTED ISOLATING CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V VERTICAL BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM W.MOUNTED ARC-CHUTE EXTENSION
3WN1071-1C...-....
DRAWOUT CIRCUIT-BREAKER 3-POLE; 80KA SIZE I/1, RTD.CONT.CURR.630A CURR.TRANSFORM.RATED CURR.500A SETTING RANGE 126 TO 315A
3WN1071-5C...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, UP TO 1000V SIZE I/1, RTD.CONT.CURR.630A CURR.TRANSFORM.RATED CURR.500A SETTING RANGE 200 TO 500A
3WN1075-2W...-....
WITHDRAWABLE LOAD INTER. SWITCH 3-POLE, SIZE I IN=800A UP TO UE=600V DC
3WN1075-5W...-....
WITHDRAWABLE LOAD INTER. SWITCH 3-POLE, SIZE I IN=800A UP TO UE=1000V DC
3WN1051-2D...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/1 IN=630A TO UE=690V 50/60 HZ ICU=80KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 252 TO 630A W.MOUNTED ARC-CHUTE EXTENSION
3WN1051-1B...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/1 IN=630A TO UE=690V 50/60 HZ ICU=80KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 160 TO 400A
3WN1051-2W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 3-POLE, SIZE I /1 IN=630A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL WITH MOUNTED ARC-CHUTE EXTENSION
3WN5361-1F...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 400 TO 1000A
3WN5361-2F...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 400 TO 1000A W.MOUNTED ARC-CHUTE EXTENSION
3WN5671-2W...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, 65KA SIZE II,RATD.CONTIN.CURR.2500A W.MOUNTED ARC-CHUTE EXTENSION
3WN5651-1K...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE II IU=2500A TO UE=690V AC 50/60HZ ICU=65KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 1000 TO 2500A
3WN5651-2K...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE II IU=2500A TO UE=690V AC 50/60HZ ICU=65KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 1000 TO 2500A W.MOUNTED ARC-CHUTE EXTENSION
3WN5651-1W...-....
FIXED-MOUNTED ISOLATING CIRCUIT-BREAKER 3-POLE, SIZE II IU=2500A TO UE=690V AC 50/60HZ ICU=65KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM
3WN5651-2W...-....
FIXED-MOUNTED ISOLATING CIRCUIT-BREAKER 3-POLE, SIZE II IU=2500A TO UE=690V AC 50/60HZ ICU=65KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM W.MOUNTED ARC-CHUTE EXTENSION
3WN1457-2W...-....
NON-WITHDR. LOAD INTER. SWITCH 4-POLE, SIZE I IN=2000A UP TO UE=600V DC CONNECTION BOTTOM VERTICAL CONNECTION TOP HORIZONTAL
3WN1457-5W...-....
NON-WITHDR. LOAD INTER. SWITCH 4-POLE, SIZE I IN=2000A UP TO UE=1000V DC CONNECTION BOTTOM VERTICAL CONNECTION TOP HORIZONTAL
3WN1433-0H...-....
FESTEINBAU-LEISTUNGSSCHALTER 4POLIG BAUGR. I, NENNDAUERSTROM 1600A WANDLER-NENNSTROM 1600A EINSTELLBEREICH 800-1600A
3WN1433-2W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE, SIZE I IN=1600A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL WITH MOUNTED ARC-CHUTE EXTENSION
3WN1433-1H...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE; SIZE I IN=1600A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL SETTING RANGE 640-1600A
3WN1433-5H...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=1600A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL SETTING RANGE 640-1600A
3WN1433-1W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE; SIZE I IN=1600A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1433-5W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE, SIZE I IN=1600A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1461-1H...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1600A TO UE=690V AC 50/60HZ ICU=80KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 640 TO 1600A
3WN1461-2W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 3-POLE, SIZE I /2 IN=1600A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM HORIZONTAL WITH MOUNTED ARC-CHUTE EXTENSION