Автоматизация / 3WN
3WN1241-5W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 3-POLE, SIZE I /1 IN=1000A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL
3WN1433-2H...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=1600A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL SETTING RANGE 640-1600A WITH MOUNTED ARC-CHUTE EXTENSION EXTENSION
3WN1451-1H...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1600A TO UE=690V AC 50/60HZ ICU=80KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 640 TO 1600A
3WN1453-1H...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE; SIZE I IN=1600A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 640-1600A
3WN5673-1K...-....
DRAW-OUT CIRCUIT-BREAKER 4-POLE; 65KA UP TO AC 500V SIZE II,RATD.CONTIN.CURR.2500A CURR.TRANSFORM.RATED CURR.2500A SETTING RANGE 1000 TO 2500A
3WN5673-2K...-....
DRAW-OUT CIRCUIT-BREAKER 4-POLE; 65KA UP TO AC 500V SIZE II,RATD.CONTIN.CURR.2500A CURR.TRANSFORM.RATED CURR.2500A SETTING RANGE 1000 TO 2500A W.MOUNTED ARC-CHUTE EXTENSION
3WN1461-5H...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1600A TO UE=1000V AC 50/60HZ ICU=25KA AT 1000V HORIZONT.BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 640 TO 1600A
3WN1461-2H...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1600A TO UE=690V AC 50/60HZ ICU=80KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP HORIZONT.BUSBAR CONNECT.BOTTOM SETTING RANGE 640 TO 1600A W.MOUNTED ARC-CHUTE EXTENSION
3WN1463-5W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE, SIZE I IN=1600A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM HORIZONTAL
3WN1443-2W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE, SIZE I IN=1600A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL WITH MOUNTED ARC-CHUTE EXTENSION
3WN1443-5W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE, SIZE I IN=1600A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL
3WN1471-2H...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, 80KA SIZE 1/2 RATD.CONTIN.CURR.1600A CURR.TRANSFORM.RATD.CURR. 1600A SETTING RANGE 640 TO 1600A W.MOUNTED ARC-CHUTE EXTENSION
3WN1473-2H...-....
WITHDRAWABLE CIRCUIT BREAKER 4-POLE, 80KA SIZE I, IN=1600A TRANSFORMER RATED CURRENT 1600A SETTING RANGE 640-1600A WITH MOUNTED ARC-CHUTE EXTENSION
3WN1243-1F...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE; SIZE I IN=1000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL SETTING RANGE 400-1000A
3WN1133-2W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE, SIZE I IN=800A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL WITH MOUNTED ARC-CHUTE EXTENSION
3WN5351-2F...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 400 TO 1000A W.MOUNTED ARC-CHUTE EXTENSION
3WN5351-1G...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 500 TO 1250A
3WN5351-2G...-....
FIXED-MOUNTED CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM SETTING RANGE 500 TO 1250A W.MOUNTED ARC-CHUTE EXTENSION
3WN5351-1W...-....
FIXED-MOUNTED ISOLATING CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM
3WN5351-2W...-....
FIXED-MOUNTED ISOLATING CIRCUIT-BREAKER 3-POLE, SIZE I/2 IU=1250A TO UE=690V AC 50/60HZ ICU=50KA AT 500V HORIZONT.BUSBAR CONNECT.ON TOP VERTIC.BUSBAR CONNECT.AT BOTTOM W.MOUNTED ARC-CHUTE EXTENSION
3WN5373-1G...-....
DRAW-OUT CIRCUIT-BREAKER 4-POLE, 50KA SIZE I, RTD.CONT.CURR.1250A CURR.TRANSFORM.RATED CURR.1250A SETTING RANGE 500 TO 1250A
3WN5373-2W...-....
DRAW-OUT CIRCUIT-BREAKER 4-POLE, 50KA SIZE I, RTD.CONT.CURR.1250A W.MOUNTED ARC-CHUTE EXTENSION
3WN1131-1W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 3-POLE; SIZE I /1 IN=800A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1155-5L...-....
NON-WITHDRAW. CIRCUIT-BREAKER 3-POLE, SIZE I IN=1000A UP TO UE=1000V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1155-2W...-....
NON-WITHDR. LOAD INTER. SWITCH 3-POLE, SIZE I IN=1000A UP TO UE=600V DC CONNECTION BOTTOM VERTICAL CONNECTION TOP HORIZONTAL
3WN1155-5W...-....
NON-WITHDR. LOAD INTER. SWITCH 3-POLE, SIZE I IN=1000A UP TO UE=1000V DC CONNECTION BOTTOM VERTICAL CONNECTION TOP HORIZONTAL
3WN1133-0A...-....
FESTEINBAU-LEISTUNGSSCHALTER 4POLIG BAUGR. I, NENNDAUERSTROM 800A WANDLER-NENNSTROM 315A EINSTELLBEREICH 157,5-315A
3WN1137-5W...-....
NON-WITHDR. LOAD INTER. SWITCH 4-POLE, SIZE I IN=1000A UP TO UE=1000V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1133-2A...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=800A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL SETTING RANGE = 158-315A WITH MOUNTED ARC-CHUTE EXTENSION
3WN1133-0B...-....
FESTEINBAU-LEISTUNGSSCHALTER 4POLIG BAUGR. I, NENNDAUERSTROM 800A WANDLER-NENNSTROM 400A EINSTELLBEREICH 200-400A
3WN1133-2B...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=800A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL SETTING RANGE 200-400A WITH MOUNTED ARC-CHUTE EXTENSION
3WN1133-0C...-....
FESTEINBAU-LEISTUNGSSCHALTER 4POLIG BAUGR. I, NENNDAUERSTROM 800A WANDLER-NENNSTROM 500A EINSTELLBEREICH 250-500A
3WN1133-2C...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=800A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL SETTING RANGE 200-500A WITH MOUNTED ARC-CHUTE EXTENSION
3WN1133-2D...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=800A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL SETTING RANGE 252-630A WITH MOUNTED ARC-CHUTE EXTENSION EXTENSION
3WN1133-0E...-....
FESTEINBAU-LEISTUNGSSCHALTER 4POLIG BAUGR. I, NENNDAUERSTROM 800A WANDLER-NENNSTROM 800A EINSTELLBEREICH 400-800A
3WN1133-2E...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=800A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL SETTING RANGE 320-800A WITH MOUNTED ARC-CHUTE EXTENSION EXTENSION
3WN1553-1H...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE; SIZE II /1 IN=2000A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 640-1600A
3WN60.1-.....-....
NON-WITHDRAWABLE CIRCUIT BREAKER 3-POLE, SIZE I IN=630A TO 690V, AC50/60HZ ICU=65KA AT 500V WITH READY-TO-CLOSE SIGNALLING SWITCH WITH MECHANICAL RECLOSING LOCK-OUT WITH TRIPPED SIGNALLING SWITCH WITH TRIPPED INDICATORS
3WN1573-1J...-....
WITHDRAWABLE CIRCUIT BREAKER 4-POLE; 80KA TO AC 500V SIZE II, IN=2000A TRANSFORMER RATED CURRENT 2000A SETTING RANGE 800-2000A
3WN1575-5L...-....
WITHDRAWABLE CIRCUIT-BREAKER 3-POLE, SIZE II IN=2500A UP TO UE=1000V DC
3WN1153-2A...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=800A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE = 158-315A WITH MOUNTED ARC-CHUTE EXTENSION
3WN1353-5G...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=1250A TO UE=1000V AC50/60HZ ICU=25KA AT 1000V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 500-1250A
3WN1353-2G...-....
NON-WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=1250A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP HORIZONTAL CONNECTION BOTTOM VERTICAL SETTING RANGE 500-1250A WITH MOUNTED ARC-CHUTE EXTENSION EXTENSION
3WN1343-2W...-....
NON-WITHDRAWABLE LOAD INTERRUPTER SWITCH 4-POLE, SIZE I IN=1250A TO UE=690V AC50/60HZ ICU=80KA AT 500V CONNECTION TOP VERTICAL CONNECTION BOTTOM HORIZONTAL WITH MOUNTED ARC-CHUTE EXTENSION
3WN1367-2W...-....
NON-WITHDR. LOAD INTER. SWITCH 4-POLE, SIZE I IN=1600A UP TO UE=600V DC CONNECTION TOP HORIZONTAL CONNECTION BOTTOM HORIZONTAL
3WN1345-5L...-....
NON-WITHDRAW. CIRCUIT-BREAKER 3-POLE, SIZE I IN=1600A UP TO UE=1000V DC CONNECTION TOP VERTICAL CONNECTION BOTTOM VERTICAL
3WN1371-1C...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE; 80KA SIZE I/2, RTD.CONT.CURR.1250A CURR.TRANSFORM.RATED CURR.500A SETTING RANGE 200 TO 500A
3WN1371-5E...-....
DRAW-OUT CIRCUIT-BREAKER 3-POLE, UP TO AC 1000V SIZE I/2, RTD.CONT.CURR.1250A CURR.TRANSFORM.RATED CURR.800A SETTING RANGE 320 TO 800A