Контрольно-измерительные приборы и оборудование / 7MA
7MA8500-8FW
IMMERSION FITTING COMPLETELY OF PP, FOR TANKS OR OPEN VESSELS, WITH IMMERSION TUBE AND PROTECTIVE CAGE, IMMERSION LENGTH UP TO 2000 MM
7MA1040-8A.
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR PH OR ORP MEASUREMENT; SINGLE MEASUREMENT 1 X PH OR 1 X ORP, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION, LOGBOOK, CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, MICROPROCESSOR CONTROLLED MANUAL ON CD (5 LANGUAGES), POWER SUPPLY: DC 24 V IN FIELD HOUSING
7MA5501-8AG78
BETRIEBSANLEITUNG, SPANISCH SIPAN TOC-100 COMPACT EQUIPO DE MEDICION PARA LA DETERMINACION DE CARBONO EN EL AGUA
7MA5000-8AB
SIPAN 2000 MEASURING EQUIPMENT FOR WATER QUALITY COMPRISING - 2-PART ANALYSIS CABINET WITH WATER GUIDING MODULE AND CLEANING MODULE - 1-PART ANALYSIS CABINET WITH ELECTRONICS MODULE MEASURED QUANTITY: REDOX POTENTIAL
7MA3100-8HA
OXYGOLD G DO SENSOR FOR NON OR LOW-CARBONATED BEVERAGE, ULTRA PURE WATER AND CHEMICAL APPLICATIONS STEAM STERILIZABLE WITH 3.1B CERTIFICATE, EX-LABEL II 1/2G EEX IA II C T4/T5/T6 ADAPTER: PG 13,5 THREAD INSTALLATION LENGTH: 120 MM DIAMETER: 12 MM SHAFTMATIERAL: SS (1.4435) SEALING MATERIAL: EPDM DEGREE OF PROTECTION: IP 68 THERMOMETER: 22 KOHM NTC INTEGR MEASURING R.: 2 PPB TO 20 PPM POLARISAT. VOLT.: 670 +/- 50 MV RESPONSE TIME T(98%)
7MA1141-8A.
SIPAN 32X ANALYZER WITH EXPLOSION PROTECTION, INTRINSIC SAFETY VERSION II 2 G EEX IA II C T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR PH OR ORP MEASUREMENT;DOUBLE MEASUREMENT 2 X PH OR 1 X PH AND 1 X ORP OR 2 X ORP, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION, LOGBOOK,CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, MICROPROCESSOR CONTROLLED, MANUAL ON CD (5 LANGUAGES), POWER SUPPLY: DC 24 V IN FIELD HOUSING
7MA5001-8AD
SIPAN 2000 MEASURING EQUIPMENT FOR WATER QUALITY COMPRISING - 3-PART ANALYSIS CABINET WITH ELECTRONICS MODULE, WATER GUIDING MODULE AND CLEANING MODULE MEASURED QUANTITY: DISSOLVED OXYGEN
7MA1010-1AA11
SIPAN PH/ORP MEASURING INSTRUMENT, STANDARD DESIGN WITH PLASTIC HOUSING POWER SUPPLY DC 24 V WITHOUT ELECTRICAL ISOLATION INPUT/OUTPUT MEASURING RANGE PH=0 TO PH=14 MEASURING SPAN DELTA PH = 14 WITHOUT DISPLAY
7MA1010-2BA21
SIPAN PH/ORP MEASURING INSTRUMENT, STANDARD DESIGN WITH PLASTIC HOUSING POWER SUPPLY AC 220 V WITHOUT ELECTRICAL ISOLATION INPUT/OUTPUT MEASURING RANGE PH=0 TO PH=14 MEASURING SPAN DELTA PH = 14 WITH ANALOG DISPLAY
7MA1010-1BA31
SIPAN PH/ORP MEASURING INSTRUMENT, STANDARD DESIGN WITH PLASTIC HOUSING POWER SUPPLY DC 24 V WITHOUT ELECTRICAL ISOLATION INPUT/OUTPUT MEASURING RANGE PH=0 TO PH=14 MEASURING SPAN DELTA PH = 14 WITH DIGITAL DISPLAY
7MA1010-2CB31
SIPAN PH/ORP MEASURING INSTRUMENT, STANDARD DESIGN WITH PLASTIC HOUSING POWER SUPPLY AC 220 V WITHOUT ELECTRICAL ISOLATION INPUT/OUTPUT MEASURING RANGE PH=0 TO PH=14 MEASURING SPAN DELTA PH = 2, 5, 10 OR 14 WITH LIMIT MONITOR AND DIGITAL DISPLAY
7MA1010-1EB51
SIPAN PH/ORP MEASURING INSTRUMENT, STANDARD DESIGN WITH PLASTIC HOUSING POWER SUPPLY DC 24 V WITH ELECTRICAL ISOLATION INPUT/OUTPUT FOR REDOX POTENTIAL MEASUREMENT MEASURING RANGE -1400...+1400MV MEASURING SPAN DELTA U = 200, 500, 1000 OR 1400 MV WITH LIMIT MONITOR AND DIGITAL DISPLAY
7MA1034-.....-....
SIPAN 34 ANALYZER FOUR-WIRE SYSTEM, FOR PH OR ORP MEASUREMENT; PROCESS VERSION, MICROPROCESSOR-CONTROLLED WITH ILLUMINATED GRAPHIC DISPLAY, MEMBRANE KEYBOARD, TREND DISPLAY, MENU-BASED OPERATION (5 LANGUAGES), MANUAL ON CD (5 LANGUAGES), DIAGNOSTIC SOFTWARE, LOGBOOK, TEMPERATURE COMPENSATION, 1 PARAMETER SET, 1 SIGNAL OUTPUT 0/4 TO 20 MA, 1 ALARM CONTACT, 1 LIMIT CONTACT, 2 DIAGNOSTIC CONTACTS
7MA1020-8BA
SIPAN PH/ORP-MP TRANSMITTER WITH MICROPROCESSOR AND - MEMBRANE KEYBOARD - DIGITAL DISPLAY - LIMIT MONITOR AND CONTACT FOR SYSTEM ALARM - 2 MEASURING RANGES - 2 OUTPUT SIGNALS 0/4 TO 20 MA - TEMPERATURE COMPENSATION - ELECTRICAL ISOLATION INSTALLED IN PLASTIC HOUSING POWER SUPPLY DC 24 V
7MA1020-8BB
SIPAN PH/ORP-MP TRANSMITTER WITH MICROPROCESSOR AND - MEMBRANE KEYBOARD - DIGITAL DISPLAY - LIMIT MONITOR AND CONTACT FOR SYSTEM ALARM - 2 MEASURING RANGES - 2 OUTPUT SIGNALS 0/4 TO 20 MA - TEMPERATURE COMPENSATION - ELECTRICAL ISOLATION INSTALLED IN PLASTIC HOUSING POWER SUPPLY AC 230 V
7MA3100-8HK
POLARIZATION MODULE G FOR OXYFERM VP AND OXYGOLD G DO SENSORS . TO STABILIZE SPARE SENSORS WITHOUT AN AMPLIFIER
7MA5000-8AD
SIPAN 2000 MEASURING EQUIPMENT FOR WATER QUALITY COMPRISING - 2-PART ANALYSIS CABINET WITH WATER GUIDING MODULE AND CLEANING MODULE - 1-PART ANALYSIS CABINET WITH ELECTRONICS MODULE MEASURED QUANTITY: DISSOLVED OXYGEN
7MA3100-8HD
OXYFERM VP DO SENSOR FOR BEVERAGE AND CHEMICAL APPLICATIONS,STEAM STERILIZABLE WITH 3.1B CERTIFICATE EX-LABEL: . II 1/2G EEX IA II C T4/T5/T6 ADAPTER: PG 13,5 TREAD CABLE: VP-PLUG (VP 6.0) INSTALLATION LENGTH: 120 MM DIAMETER: 12 MM SHAFTMATERIAL: SS (1.4435) SEALING MATERIAL: EPDM DEGREE OF PROTECTION: IP 68 THERMOMETER: 22 KOHM NTC INTEGR MEASURING R.: 10 PPB TO 20 PPM POLARISATIONVOLT.: 670 +/- 50 M OPERATION TEMPERATURE: 0-130 C PRESSURE RANGE: 0,5-4 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
7MA3100-8CA
O2 SENSOR FOR DRINKS INDUSTRY 120 MM LONG MATCHING THE ATTACHMENT FITTING 7MA8500-8EA (INCL. 5 M CABLE) PRESSURE EQUIPMENT DIREKTIVE F. GAS 2/LIQUIDS 1 ART. 3.3 SEP
7MA8500-8DQ
PLUG-CABLE COMBINATION FOR PH COMBINATION ELECTRODE, INCL. PT1000, CABLE LENGTH 5M
7MA3100-8HE
OXYFERM MEMBRANE KIT FOR OXYFERM VP DO SENSOR 3 MEMBRANE CAPS OXYLYTE-ELECTROLYTE 20 ML 1 PIPETTE . 3 O-RINGS (EPDM) ABRASIVE PAPER
7MA3100-8CB
O2 SENSOR FOR DRINKS INDUSTRY 220 MM LONG MATCHING THE REPLACEMENT FITTING 7MA8500-8EB
7MA3100-8CC
OXYGEN SENSOR FOR DISSOLVED O2 IN ULTRA-PURE WATER ONLY FOR USE WITH SIPAN 34 CABLE: 5 M FIXED CABLE MEASURING RANGE 0..10 MICRO G/L TO 0.. 1000 MICRO G/L OPERATION TEMP.: 0 TO 50 GRAD C PRESSURE RANGE: 1 - 10 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 2/LIQUIDS 1 ART. 3.3 SEP
7MA3100-8HG
OXYSENS DO SENSOR FOR WATER AND WASTEWATER APPLICATIONS MAINTENANCE-FREE EX-LABEL: . II 1/2G EEX IA II C T4/T5/T6 ADAPTER: PG 13,5 THREAD CABLE: 5 M FIXED AND SEALED INSTALLATION LENGTH: 120 MM DIAMETER: 12 MM SHAFTMATIERAL: . SS (1.4435) AND PEEK SEALING MATERIAL: EPDM . DEGREE OF PROTECTION: IP 68 THERMOMETER: 22 KOHM NTC INTEGR MEASURING R.: 40 PPB TO 20 PPM POLARISATIONVOLT.: 670 +/- 50 M OPERATION TEMPERATURE: 0-60 C PRESSURE RANGE: 0,5-4 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
7MA3100-8HH
CABLE WITH VP PLUG CONNECTOR FOR OXYFERM VP AND OXYGOLD G DO SENSORS CABLE LENGTH: 5 M CABLE DIAMETER: 7.5 MM
7MA3100-8CE
OXYGEN SENSOR FOR DISSOLVED O2 IN WASTE WATER ONLY FOR USE WITH SIPAN 34 FIXED IN PVC IMMERSION FITTING IMMERSION LENGTH: 550 MM CABLE: 7 M FIXED CABLE RANGE 0... 5 MG/L TO 0... 60 MG/L OPERATION TEMP.: 0 TO 50 GRAD C MAX. PRESSURE: 1,5 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 2/LIQUIDS 1 ART. 3.3 SEP
7MA3100-8HJ
FLOWFITTING FOR DO SENSORS WITH ONE SENSOR CONNECTION ADAPTER: PG 13,5 THREAD LENGTH OF SENSOR: 120 MM MATERIAL: SS (1.4435) OPERATION PRESSURE: 0 - 16 BAR OPERATION TEMPERATURE: 130 C PROCESS CONNECTION: . 10 MM SWAGELOCK . PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
7MA3100-8CF
OXYGEN SENSOR FOR DISSOLVED O2 IN WASTE WATER ONLY FOR USE WITH SIPAN 34 FOR FITTING WITH SENSOR HANDLE OR SWINGING SUPPORT CABLE: 7 M FIXED CABLE RANGE 0... 5 MG/L TO 0... 60 MG/L OPERATION TEMP.: 0 TO 50 GRAD C PRESSURE RANGE: 1 - 10 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 2/LIQUIDS 1 ART. 3.3 SEP
7MA3100-8EF
OXYGEN SENSOR FOR DISSOLVED O2 IN ULTRA-PURE WATER ONLY FOR USE WITH SIPAN 34 MEASURING RANGE 0..10 MICRO G/L TO 0...1000 MICRO G/L COMPRISING: O2 SENSOR WITH 5 M FIXED CABLE 7MA3100-8CC FLOW FITTING, COMPLETE 7MA8500-8AM, DIAPHRAGM KIT 1 7MA8500-8CC, CLEANING ATTACHMENT 7MA8500-8DL PRESSURE EQUIPMENT DIREKTIVE F. GAS 2/LIQUIDS 1 ART. 3.3 SEP
7MA1140-8A.
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR PH OR ORP MEASUREMENT; DOUBLE MEASUREMENT 2 X PH OR 2 X ORP OR 1 X PH AND 1 X ORP, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION, LOGBOOK, CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, MICROPROCESSOR CONTROLLED, MANUAL ON CD (5 LANGUAGES), POWER SUPPLY: DC 24 V IN FIELD HOUSING
7MA2000-8CB
SIPAN 2EL CONDUCTIVITY SENSOR WITH CONCENTRICALLY ARRANGED ELECTRODES, CELL CONSTANT 1.16 CM-1, WITH BUILT-IN COMPENSATION THERMOMETER AND UNION NUT PRESSURE EQUIPMENT DIREKTIVE F. GAS 2/LIQUIDS 1 ART. 3.3 SEP
7MA1141-8AD
SIPAN 32 ANALYZER WITH EXPLOSIO PROTECTION, INTRINSIC SAFETY VERSION II 2 G EEX IA II C T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR PH OR ORP MEASUREMENT; DOUBLE MEASUREMENT 2 X PH OR 2 X ORP OR 1 X PH AND 1 X ORP, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION, LOGBOOK, TEMPERATURE COMPENSATION, MICROPROCESSOR CONTROLLED, MANUAL ON CD(5 LANGUAGES), POWER SUPPLY: DC 24 V IN FIELD HOUSING COMMUNICATION VIA PROFIBUS PA
7MA5000-8AA
SIPAN 2000 MEASURING EQUIPMENT FOR WATER QUALITY COMPRISING - 2-PART ANALYSIS CABINET WITH WATER GUIDING MODULE AND CLEANING MODULE - 1-PART ANALYSIS CABINET WITH ELECTRONICS MODULE MEASURED QUANTITY: PH VALUE
7MA5000-8AC
SIPAN 2000 MEASURING EQUIPMENT FOR WATER QUALITY COMPRISING - 2-PART ANALYSIS CABINET WITH WATER GUIDING MODULE AND CLEANING MODULE - 1-PART ANALYSIS CABINET WITH ELECTRONICS MODULE MEASURED QUANTITY:CONDUCTIVITY
7MA2000-8PX5
DUMMY PLUG OUT OF SS 316 SENSORADAPTER: 3/4 INCH NPT THREAD TOTAL LENGTH: 31 MM MAX: TEMPERATURE: 150 DEG. C MAX. PRESSURE: 10 BAR