7SS1310-0NA00
SOL.ST.DIFFERENTIAL RELAY FOR BUSBARS IN SIPAC-Z SUBRACK,28SPS W.1 STABILIZING MODULE NOMINAL FREQUENCY: 50HZ W/O TEST AND OPERATING MODULE
7SS1330-0NA00
SOL.ST.DIFFERENTIAL RELAY FOR BUSBARS IN SIPAC-Z SUBRACK,28SPS W.3 STABILIZING MODULES NOMINAL FREQUENCY: 50HZ W/O TEST AND OPERATING MODULE
7SS1311-1NA00
SOL.ST.DIFFERENTIAL RELAY FOR BUSBARS IN SIPAC-Z SUBRACK,28SPS W.1 STABILIZING MODULE NOMINAL FREQUENCY: 60HZ WITH OPERATING MODULE 7TW3210-0
7SS1331-0NA00
SOL.ST.DIFFERENTIAL RELAY FOR BUSBARS IN SIPAC-Z SUBRACK,28SPS W.3 STABILIZING MODULES NOMINAL FREQUENCY: 60HZ W/O TEST AND OPERATING MODULE
7SS1331-1NA00
SOL.ST.DIFFERENTIAL RELAY FOR BUSBARS IN SIPAC-Z SUBRACK,28SPS W.3 STABILIZING MODULES NOMINAL FREQUENCY: 60HZ WITH OPERATING MODULE 7TW3210-0
7SS132.-..A00
SOLID-ST.DIFFERENTIAL RELAY FOR BUSBARS IN THE RACK W.2 STABILIZING MODULES
7SS134.-..A.0
SOLID-ST.DIFFERENTIAL RELAY FOR BUSBARS IN THE CASE W.4 STABILIZING MODULES
7SS135.-..A00
SOLID-ST.DIFFERENTIAL RELAY FOR BUSBARS IN THE SUBRACK WITH 5 STABILIZ.MODULES
7SS1321-1NA00
SOL.ST.DIFFERENTIAL RELAY FOR BUSBARS IN SIPAC-Z SUBRACK,28SPS W.2 STABILIZING MODULES NOMINAL FREQUENCY: 60HZ WITH OPERATING MODULE 7TW3210-0
7SS5030-.....-.A..
NUMERICAL STATION PROTECTION WITH SUMMATION TRANSFORMER CIRCUIT-BREAKER FAILURE PROTEC. FREQUENCY 50/60HZ FOR TRIPLE BUSBAR WITHOUT TRANSFER BUS TWO TRIPPING CONTACTS PER BAY BAY OUT OF SERVICE A. INTERTRIP
7SS8600-3B
STABILIZING UNIT 50/60HZ F.3 SYSTEMS,BUSBARS PROTECTION CASE W/CAP F.SURFACE MOUNTING FRONT CONN.,SHORT TERMINAL COV. 03063
7SS5220-5AG32-1AA0
DISTRIBUTED BUSBAR/ CIRCUIT BREAKER FAILURE PROTECT. 7SS52 CENTRAL UNIT, 50/60HZ, FIRMWARE VERSION: V4 RATED AUXILIARY VOLTAGE: DC 220V TO 250V IN SUBRACK ES902C REGION WORLD, LANGUAGE: RUSSIAN (LANGUAGE CHANGEABLE) PROTOCOL IEC 60870-5-103, OPTICAL 820NM, ST-PLUG SERVICE INTERFACE: DIGSI 4, ELECTRICAL RS485 WITHOUT ADDITIONAL FUNCTION EQUIPPED FOR 8 BAYS
7SS5000-.....-.A..
NUMERICAL STATION PROTECTION WITH SUMMATION TRANSFORMER CIRCUIT-BREAKER FAILURE PROTEC. FREQUENCY 50/60HZ F.SINGLE BUSBAR TWO TRIPPING CONTACTS PER BAY BAY OUT OF SERVICE
7SS112.-....0
SOLID-ST.DIFFERENTIAL RELAY F.DOUBLE BUSBARS IN THE CASE,EQUIPPED W.2MEASG.UNITS AND WIRED F.2 MEASG.UNITS
7SS9000-2F
MONITOR F. BUSBAR PROTECTION SUPPLY VOLTAGE: DC 60V CASE W. CAP F. FLUSH MOUNTING
7SS5000-.....-.B..
NUMERICAL STATION PROTECTION WITH SUMMATION TRANSFORMER CIRCUIT-BREAKER FAILURE PROTEC. FREQUENCY 50/60HZ F.SINGLE BUSBAR FOUR TRIPPING CONTACTS PER BAY BAY OUT OF SERVICE
7SS111.-..A00
SOLID ST.DIFFERENTIAL RELAY F.SINGLE BUSBARS IN SUBRACK,EQUIPPED W.1 MEASG.UNIT AND F.2 MEASG.UNITS,WIRED