Энергетика PTD / 8BJ
8BJ2080-5FA0.-.AA0
MOUNTING OF CURR.TRAFO F.24KV IN LOWER SECTION OF BUS RISER PANEL TYPE I
8BJ2080-5WA00-8AA0
BARRIER RAIL FOR FITTING IN THE DOOR FRAME ON THE REAR OF HV COMPART.DOOR FOR BUS RISER PANEL TYPE I 24KV
8BJ2080-0XF00-1CC0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 24KV 20KA DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT BELOW 300MM RIGHT OVER 300MM
8BJ5080-1LF26-....
WITHDRAWABLE SECTION FOR 3CG VACUUM SWITCH WITH CARRIAGE MECHANISM AN CONTACT ARMS 24KV 20KA/3S 630A
8BJ2060-0XF00-1CE0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 17.5KV 20KA; DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT AND RIGHT BELOW 300MM
8BJ2060-0LE0.-....
DRAW-OUT METERING SECTION WITH CARRIAGE MECHANISM AND CONTACT ARMS, AND WITH FITTING AND WIRING OF THE VOLTAGE TRANSFORMERS 17.5KV 16KA
8BJ2060-0XG00-1CC0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 17.5KV 25KA; DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT BELOW 400MM RIGHT OVER 400MM
8BJ2060-0LF0.-....
DRAW-OUT METERING SECTION WITH CARRIAGE MECHANISM AND CONTACT ARMS, AND WITH FITTING AND WIRING OF THE VOLTAGE TRANSFORMERS 17.5KV 20KA
8BJ2060-0XG00-1CD0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 17.5KV 25KA; DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT OVER 300MM RIGHT BELOW 300MM
8BJ2060-0LG0.-....
DRAW-OUT METERING SECTION WITH CARRIAGE MECHANISM AND CONTACT ARMS, AND WITH FITTING AND WIRING OF THE VOLTAGE TRANSFORMERS 17.5KV 25KA
8BJ2060-0XG00-1CE0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 17.5KV 25KA; DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT AND RIGHT BELOW 300MM
8BJ2060-0VA00-0AA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR FOR SWITCHPANEL 17.5KV FOR 3 SINGLE-POLE VOLT.TRANSF.
8BJ2060-1AE00-...0
FRAME FOR DRAW-OUT PANEL WITH DOOR, GUIDE RAILS FOR THE PROTECTIVE BARRIER, SUPPORT RAILS FOR TAKING THE DRAW-OUT UNIT, 17.5KV, 16KA
8BJ2060-1AF00-...0
FRAME FOR DRAW-OUT PANEL WITH DOOR, GUIDE RAILS FOR THE PROTECTIVE BARRIER, SUPPORT RAILS FOR TAKING THE DRAW-OUT UNIT, 17.5KV, 20KA
8BJ2060-0VA00-0CA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR FOR SWITCHPANEL 17.5KV FOR 3 SINGLE-POLE VOLT.TRANSF. AND EARTH-FAULT WINDING AND DAMPING RESISTOR
8BJ2060-1AG00-...0
FRAME FOR DRAW-OUT PANEL WITH DOOR, GUIDE RAILS FOR THE PROTECTIVE BARRIER, SUPPORT RAILS FOR TAKING THE DRAW-OUT UNIT, 17.5KV, 25KA
8BJ2060-0VA00-0DA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR FOR SWITCHPANEL 17.5KV FOR 1 TWO-POLE VOLT.TRANSF. BETWEEN L1 AND L2
8BJ2060-1BA00-....
LOW-VOLTAGE COMPARTMENT W.DOOR,EQUIPMENT CARRIER PLATE TERMINAL STRIP,WIRING DUCTS AND LV CONNECTOR F.SWITCHGEAR 17.5KV INTEGRATED IN DRAW-OUT PANEL
8BJ2060-0VA00-0EA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR FOR SWITCHPANEL 17.5KV FOR 2 TWO-POLE VOLT.TRANSF.
8BJ2060-0VA00-1AA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR,IN LOWER SECTION OF THE METERING PANEL FOR SWITCHPANEL 17.5KV FOR 3 SINGLE-POLE VOLT.TRANSF.
8BJ2060-1DA3.-.AA0
BUSBAR WITHIN A CUBICLE F.ALL ELECTRICAL CONNECTIONS INCLUDING MATING CONTACTS IN THE DRAW-OUT PANEL 17.5KV, 1250A
8BJ2060-0VA00-1BA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR,IN LOWER SECTION OF THE METERING PANEL FOR SWITCHPANEL 17.5KV FOR 3 SINGLE-POLE VOLT.TRANSF. AND EARTH-FAULT WINDING
8BJ2060-1DA5.-.AA0
BUSBAR WITHIN A CUBICLE F.ALL ELECTRICAL CONNECTIONS INCLUDING MATING CONTACTS IN THE DRAW-OUT PANEL 17.5KV, 2000A
8BJ2060-0VA00-1CA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR,IN LOWER SECTION OF THE METERING PANEL FOR SWITCHPANEL 17.5KV FOR 3 SINGLE-POLE VOLT.TRANSF. AND EARTH-FAULT WINDING AND DAMPING RESISTOR
8BJ2060-1FA0.-.AA0
MOUNTING OF CURR.TRAFO F.17.5KV ON THE CABLE CONNECT.COMPART. OF THE DRAW-OUT PANEL
8BJ2060-1GA0.-.AA0
VOLT.TRANSFORMER INSTALLATION FOR 17.5KV ON THE CABLE CONNECTION COMPARTMENT OF THE DRAW-OUT PANEL
8BJ2060-0VA00-1EA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR,IN LOWER SECTION OF THE METERING PANEL FOR SWITCHPANEL 17.5KV FOR 2 TWO-POLE VOLT.TRANSF.
8BJ2060-5BA00-....
LOW-VOLTAGE COMPARTMENT W.DOOR,EQUIPMENT CARRIER PLATE TERMINAL STRIP,WIRING DUCTS AND LV CONNECTOR F.SWITCHGEAR 17.5KV INTEGRATED IN BUS RISER PANEL TYPE I
8BJ2060-5DA2.-.AA0
BUSBAR WITHIN A CUBICLE F.ALL ELECTRICAL CONNECTIONS INCLUDING MATING CONTACTS IN THE BUS RISER PANEL TYPE I 17.5KV, 630A
8BJ2060-0XA30-7CA0
SURFACE OF THE SCREWED JOINTS OF MAIN CIRCUIT AND EARTH.BUSBARS TINNED, MOVING CONTACTS SILVER-PLATED F.1 PANEL 17.5KV 1250A
8BJ2061-6FA0.-.AA0
MOUNTING OF CURR.TRAFO F.17.5KV ON THE CONNECT.COMPART. OF BUSBAR CONNECTION PANEL TYPE II
8BJ2002-0WA00-6BB0
CONNECTING POINTS FOR EARTHING ACCESSORIES MOUNTED ON THE OUTGOING FEEDER BALL TERMINAL STUD BALL DIAMETER 25 MM
8BJ2002-0XA00-3CA0
LABEL SET F.OPERATING INSTRUCTIONS ON THE SWITCHGEAR PANEL FRONT IN FRENCH LANGUAGE
8BJ2002-0XA00-3DA0
LABEL SET F.OPERATING INSTRUCTIONS ON THE SWITCHGEAR PANEL FRONT IN SPANISH LANGUAGE
8BJ5020-1NE50-0...
DISCONNECTOR LINK SECTION WITH CARRIAGE MECHANISM, CONTACT ARMS AND COPPER BARS 7.2KV 16KA/3S 2000A
8BJ2040-0WA00-2BB0
ASSEMBLY KIT FOR CAPACITIVE VOLTAGE PICK-OFF AT FEEDER 3POLE,W.WIRING AND SOCKET IN SWITCH PANEL FRONT F.SWITCHPANEL 7.2KV W.2 CAP.SEGM.ASSEMBLIES IN THE INSULATORS F.1CAP.SEGM.ASSEMBLY IN THE CURR.TRANSFORMER
8BJ2040-1MF4.-....
DRAW-OUT SECTION FOR CIRCUIT-BREAKER WITH CARRIAGE MECHANISM AND CONTACT ARMS F.DRAW-OUT PANEL 12KV, 20KA, 1600A
8BJ2040-0WA00-2BC0
ASSEMBLY KIT FOR CAPACITIVE VOLTAGE PICK-OFF AT FEEDER 3POLE,W.WIRING AND SOCKET IN SWITCH PANEL FRONT F.SWITCHPANEL 7.2KV
8BJ2040-1MF5.-....
DRAW-OUT SECTION FOR CIRCUIT-BREAKER WITH CARRIAGE MECHANISM AND CONTACT ARMS F.DRAW-OUT PANEL 12KV, 20KA, 2000A
8BJ2040-0WA00-2BD0
ASSEMBLY KIT FOR CAPACITIVE VOLTAGE PICK-OFF AT FEEDER 3POLE,W.WIRING AND SOCKET IN SWITCH PANEL FRONT F.SWITCHPANEL 7.2KV W.3 CAP.SEGM.ASSEMBLIES IN THE CURR.TRANSFORMER
8BJ2040-1MF6.-....
DRAW-OUT SECTION FOR CIRCUIT BREAKER WITH CARRIAGE MECHANISM AND CONTACT ARMS F.DRAW-OUT PANEL 12KV 20KA 2500A
8BJ2040-0WA01-1AA0
ASSEMBLY KIT FOR 1 CABLE TRANSFORMER W.WIRING TO LV CUBICLE AND INSTALL.PARTS F.TRANSFORMER UNASSEMBLED F.SWITCH PANEL 12KV
8BJ2040-1MG2.-....
DRAW-OUT SECTION FOR CIRCUIT-BREAKER WITH CARRIAGE MECHANISM AND CONTACT ARMS F.DRAW-OUT PANEL 12KV, 25KA, 630A
8BJ2040-1MG3.-....
DRAW-OUT SECTION FOR CIRCUIT-BREAKER WITH CARRIAGE MECHANISM AND CONTACT ARMS F.DRAW-OUT PANEL 12KV, 25KA, 1250A