Энергетика PTD / 8BJ
8BJ2044-1DA50-1AA0
BUSBAR WITHIN A CUBICLE FOR ALL ELECTRICAL CONNECTIONS INCLUDING MATING CONTACTS IN THE DRAW-OUT PANEL IN BACK-TO-BACK ARRANGEMENT 12KV 2000A WITH INSULATED RAILS BETWEEN BUSBARS AND UPPER MATING CONTACTS FOR DRAW-OUT PANEL
8BJ2060-5DA5.-.AA0
BUSBAR WITHIN A CUBICLE F.ALL ELECTRICAL CONNECTIONS INCLUDING MATING CONTACTS IN THE BUS RISER PANEL TYPE I 17.5KV, 2000A
8BJ2060-0XA50-7AA0
SURFACE OF THE SCREWED JOINTS OF MAIN CIRCUIT AND EARTH.BUSBAR TINNED, MOVING CONTACTS SILVER-PLATED F.1 PANEL 17.5KV 2000A
8BJ5083-0CA00-....
LOW-VOLTAGE COMPARTMENT WITH DOOR EQUIPMENT MOUNTING PLATE, SECTIONAL BAR WITH TERMINALS AND WIRING DUCTS FOR METERING PANEL 24KV, 800MM PANEL WIDTH
8BJ2060-0XE00-1CB0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 17.5KV 16KA; DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT AND RIGHT GREATER 300MM
8BJ2052-0XE00-1CD0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 15KV 16KA; DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT OVER 300MM RIGHT BELOW 300MM
8BJ2052-6KF30-0...
DISCONNECTOR LINK FOR DRAW-OUT PANEL WITH CARRIAGE MECHANISM, CONTACT ARMS AND COPPER BUSBARS 15KV 20KA 120A
8BJ2086-6AF00-3...
FRAME FOR DRAW-OUT PANEL IN BACK-TO-BACK ARRANGEMENT PANEL WIDTH 800MM W.DOOR, GUIDE RAILS FOR PROTECTIVE BARRIER,RAILS F.TAKING THE DRAW-OUT UNIT 24 KV 20KA
8BJ2086-7DA20-0AA0
BUSBAR WITHIN A CUBICLE FOR ALL ELECTRICAL CONNECTIONS INCLUDING MATING CONTACTS IN BUS COUPLER/BUS RISER PANEL TYPE I 24KV 630A
8BJ2086-7DA30-0AA0
BUSBAR WITHIN A CUBICLE FOR ALL ELECTRICAL CONNECTIONS INCLUDING MATING CONTACTS IN BUS COUPLER/BUS RISER PANEL TYPE I 24KV 1250A
8BJ2086-6DA30-0AA0
BUSBAR WITHIN A CUBICLE FOR ALL ELECTRICAL CONNECTIONS INCLUDING MATING CONTACTS IN THE DRAW-OUT PANEL IN BACK-TO-BACK ARRANGEMENT 24KV 1250A
8BJ2086-6HE00-....
EARTHING SWITCH IN THE CABLE CONNECTION COMPARTMENT OF THE DRAW-OUT PANEL IN BACK-TO-BACK ARRANGEMENT 24 KV 16KA
8BJ2086-8BA00-....
LOW VOLTAGE COMPARTMENT W.DOOR,EQUIPM.CARRIER PLATE TERMINAL STRIPS, WIRING DUCTS AND LV CONNECTOR F.SWITCHGEAR 24KV INTEGRATED IN BUS COUPLER/BUS RISER PANEL TYPE II
8BJ2086-7AE00-3A..
FRAME FOR BUS COUPLER/BUS RISER PANEL TYPE I, PANEL WIDTH 800MM W.DOOR AND SUPP.RAILS F.TAKING THE METERING PANEL 24 KV 16KA
8BJ2086-8DA20-0AA0
BUSBAR WITHIN A CUBICLE FOR ALL ELECTRICAL CONNECTIONS IN BUS COUPLER/BUS RISER PANEL TYPE II 24KV 630A
8BJ2086-8DA30-0AA0
BUSBAR WITHIN A CUBICLE FOR ALL ELECTRICAL CONNECTIONS IN BUS COUPLER/BUS RISER PANEL TYPE II 24KV 1250A
8BJ2060-0XF00-1CD0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 17.5KV 20KA; DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT OVER 300MM RIGHT BELOW 300MM
8BJ2020-0LE0.-....
DRAW-OUT METERING SECTION WITH CARRIAGE MECHANISM AND CONTACT ARMS, AND WITH FITTING AND WIRING OF THE VOLTAGE TRANSFORMERS 7.2KV 16KA
8BJ2020-0LF0.-....
DRAW-OUT METERING SECTION WITH CARRIAGE MECHANISM AND CONTACT ARMS, AND WITH FITTING AND WIRING OF THE VOLTAGE TRANSFORMERS 7.2KV 20KA
8BJ2020-0LG0.-....
DRAW-OUT METERING SECTION WITH CARRIAGE MECHANISM AND CONTACT ARMS, AND WITH FITTING AND WIRING OF THE VOLTAGE TRANSFORMERS 7.2KV 25KA
8BJ2020-0VA00-0BA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR FOR SWITCHPANEL 7.2KV F.3 SINGLE-POLE VOLT.TRANSF. AND EARTH-FAULT WINDING
8BJ2020-0VA00-0EA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR FOR SWITCHPANEL 7.2KV F.2 TWO-POLE VOLT.TRANSF.
8BJ2020-0VA00-1CA0
VOLTAGE TRANSFORMER FITTING AT THE BUSBAR,IN LOWER SECTION OF THE METERING PANEL FOR SWITCHPANEL 7.2KV F.3 SINGLE-POLE VOLT.TRANSF. AND EARTH-FAULT WINDING AND DAMPING RESISTOR
8BJ2020-0VA04-1AA0
PANEL VENTILATION WITH PROD-PROOF VENTILATION SLITS IN DOOR AND COVER PLATE FOR SWITCHPANEL 7.2KV OPEN-CIRCUIT VENTIL. W/O FAN
8BJ2020-0VA04-2MB0
PANEL VENTILATION WITH PROD-PROOF VENTILATION SLITS IN DOOR AND COVER PLATE FOR SWITCHPANEL 7.2KV FORCED VENTILATION WITH FAN 220V AC, 50HZ CONTROL WITH 1 THERMOSTAT FOR CLOSING
8BJ2020-1VA37-2CA0
SPECIAL CONNECTING LINKS FOR DRAW-OUT PANEL IN FACE-TO-FACE ARRANGEMENT 7.2KV 1250A; 2 CABLES PER PHASE FOR EXTERN.CONNECTION 2 CABLES PER PHASE FOR PANEL B CABLE CONNECTION WITH CABLE CONNECTOR
8BJ2020-0XF00-1CC0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 7.2KV 20KA DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT BELOW 300MM RIGHT OVER 300MM
8BJ5082-1NF30-2...
DISCONNECTOR LINK SECTION WITH CARRIAGE MECHANISM, CONTACT ARMS AND COPPER BARS 24KV 20KA/3S 1250A
8BJ5082-1NF30-3...
DISCONNECTOR LINK SECTION WITH CARRIAGE MECHANISM, CONTACT ARMS AND COPPER BARS 24KV 20KA/3S 1250A
8BJ5082-1NG20-1...
DISCONNECTOR LINK SECTION WITH CARRIAGE MECHANISM, CONTACT ARMS AND COPPER BARS 24KV 25KA/3S 630A
8BJ5082-1EA30-0AA2
PANEL BUSBAR INCL. MATING CONTACTS IN THE WITHDRAWABLE PANEL B IN BACK-TO-BACK ARRANGEMENT 24KV 1250A, 800 MM PANEL WIDTH
8BJ5082-1EA30-1AA0
PANEL BUSBAR INCL. MATING CONTACTS WITH INSULATED BARS BETWEEN BUSBARS AND UPPER MANTING CONTACTS IN WITHDRAQABLE PANEL 24KV 1250A
8BJ5082-1NG20-3...
DISCONNECTOR LINK SECTION WITH CARRIAGE MECHANISM, CONTACT ARMS AND COPPER BARS 24KV 25KA/3S 630A
8BJ5082-6EA30-0AA2
PANEL BUSBAR IN BUS RISER PANEL TYPE II FOR BUSBAR COUPLER, FIELD B IN BACK-TO-BACK ARRANGEMENT 24KV 1250A, 800 MM PANEL WIDTH
8BJ5082-1LG26-....
WITHDRAWABLE SECTION FOR 3CG VACUUM SWITCH WITH CARRIAGE MECHANISM AN CONTACT ARMS 24KV 25KA/3S 630A
8BJ2020-0XH00-1CE0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 7.2KV 31.5KA DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT AND RIGHT BELOW 300MM
8BJ2020-0XJ00-1CE0
END WALLS (4PCS) FOR LATERAL PLANT TERMINATION FOR SWITCHGEAR IN BACK-TO-BACK ARRANGEMENT 7.2KV 40KA DISTANCE BETWEEN SYSTEM END WALL AND LATERAL BUILDING LEFT AND RIGHT BELOW 300MM
8BJ5020-1KH30-....
WITHDRAWABLE SECTION FOR 3AH VACUUM CIRCUIT-BREAKER WITH CARRIAGE MECHANISM AN CONTACT ARMS 7.2KV 31.5KA/3S 1250A
8BJ5020-1KJ60-....
WITHDRAWABLE SECTION FOR 3AH VACUUM CIRCUIT-BREAKER WITH CARRIAGE MECHANISM AN CONTACT ARMS 7.2KV 40KA/3S 2500A
8BJ5020-1NJ60-3...
DISCONNECTOR LINK SECTION WITH CARRIAGE MECHANISM, CONTACT ARMS AND COPPER BARS 7.2KV 40KA/3S 2500A
8BJ5020-5CA00-....
LOW-VOLTAGE COMPARTMENT WITH DOOR EQUIPMENT MOUNTING PLATE, SECTIONAL BAR WITH TERMINALS, WIRING DUCTS AND LOW-VOLTAGE CONNECTOR FOR BUS RISER PANEL TYPE I 7.2KV, 800MM PANEL WIDTH
8BJ5020-5CA02-....
LOW-VOLTAGE COMPARTMENT WITH DOOR EQUIPMENT MOUNTING PLATE, SECTIONAL BAR WITH TERMINALS, WIRING DUCTS AND LOW-VOLTAGE CONNECTOR FOR BUS RISER PANEL TYPE I 7.2KV, 800MM PANEL WIDTH LV-COMP UNEQUIPPED ADVANCE DEL.