Контрольно-измерительные приборы и оборудование / 7MB
7MB1940-6AA06
SCREW CONNECTION G1/4 MADE OF POLYVINYLIDENE FLUORIDE FOR TEFLON HOSE WITH 6MM OUTER DIAMETER
7MB1943-2FE06
Пробоотборная трубка HASTELLOY C4, L=1000 MM, D=12 MM, температура до 400 C.
7MB1943-2BA68
3/2-WAY SOLENOID VALVE MADE OF PTFE, EXPLOSION-PROOF TO 2G EEX ED II T4, POWER SUPPLY 24 V
7MB1943-2FE07
Керамический фильтр L=478 MM, 2 MICRON, температура до 1000 C, DN65 PN6 адаптер нержавеющая сталь 1.4571
7MB1943-0BC01
WEATHER PROTECTION HOOD FOR REFLECTOR OMD41-R... OR FOR TRANSCEIVER UNIT OMD41-M...
7MB1943-2FE08
Пробоотборная трубка INCONEL 600, L=1000 MM, D=12 MM, температура до 1000 C.
7MB1943-2FE12
Пробоотборная трубка STAINLESS STEE, L=1000 MM, D=12 MM, температура до 600 C.
7MB1943-3AA25
HOSE PUMP EXPLOSION-PROOF VERSION, PUMP CAPACITY APPROX.0.3 L/H POWER SUPPLY AC 50HZ 230V
7MB1943-0CA01
RM210 dust concentration measuring equipment 60./60., without quick-acting shut-off unit, for stack internal diameters 501-1000mm comprising: transceiver unit r210-2m11 connection unit RM210-a1 90-260V with cable 3m long software mepa RM210 in 5 languages mounting flange 60./60., st.37 light absorber 60., st37 178x600mm purging air unit 2bh13; three-phase motor 200 to 480V 50/60HZ depending on connection mode purging air hose, 40mm diameter 5m long
7MB1943-2FF01
GAS SAMPLING PROBE WITH PNEUMATICALLY DRIVEN SHUT-OFF VALVE, HEATED, WITH WEATHERPROOF COVER, HEATING ADJUSTABLE AT THE INSTALLED CONTROLLER WITH HIGH AND LOW TEMPERATURE ALARM, BACKFLUSH CONNECTION, POWER SUPPLY 230 VAC, 50/60 HZ
7MB1943-0CA02
RM210 dust concentration measuring equipment 60./60., without quick-acting shut-off unit, for stack internal diameters 1001-1500mm comprising: transceiver unit r210-2m11 connection unit RM210-a1 90-260V with cable 3m long software mepa RM210 in 5 languages mounting flange 60./60., st.37 light absorber 60., st37 244,5x700mm purging air unit 2bh13; three-phase motor 200 to 480V 50/60HZ depending on connection mode purging air hose, 40mm diameter 5m long
7MB1943-2FF02
GAS SAMPLING PROBE WITH PNEUMATICALLY DRIVEN SHUT-OFF VALVE, WEATHERPROOF COVER, REGULATED HEATING WITH ALARM OUTPUT AND BACKFLUSH CONNECTION, POWER SUPPLY 230 VAC, 50/60 HZ
7MB1943-2AC44
Filter housing made of stainless steel 1.4404 (SS316L) without filter cartridge
7MB1943-1LA08
TWO-STAGE PRESSURE REDUCER WITH CONTACT MANOMETER ON THE HIGH-PRESSURE SIDE FOR CONNECTION TO GAS BOTTLES
7MB1943-0DA02
OMD41-02 dust concentration measuring equipment, without quick-acting shut-off unit f.stack intern.diam. 6-10m tueV approved for a measuring range of extinction: 0 to 0,3 comprising: transceiver unit OMD41-m221 reflector OMD41-r22; cable from transceiver to reflector 10m connection unit OMD41-a3, 100-240V ac; with cable 2m incl.software mepa in 5 langua. 2 mounting flanges with tube d=70,2mm, l=130mm, mat.st.37 2 mounting sets for flanges purging air unit 2bh13; with three-phase motor 200 to 480V 50/60HZ dep.on connection mode incl.purging air hose,10m long
7MB1943-3BB02
COMPRESSOR GAS COOLER WITH 1 GAS DUCT, GAS FLOW 100 L/H POWER SUPPLY AC 50/60HZ 115V; 120VA; 1.4A; WITH TEMPERATURE MONITORING, DIMENSIONS (HXWXD) 247X298X272 WITHOUT DISPOSAL OF CONDENSATION
7MB1943-3BB00
Compressor gas cooler with 1 gas duct, gas flow 125 l/h power supply AC 50HZ 230V; 180Va; 1.1a; with temperature monitoring, dimensions (hxwxd) 250x300x400 without disposal of condensation
7MB1943-0DA04
OMD41-02 dust concentration measuring equipment, with quick-acting shut-off unit 230V 50/60HZ, for stack id 0,5-2m tueV approved for a measuring range of extinction: 0 to 0,3 comprising: transceiver unit OMD41-m221 reflector OMD41-r23;10m connect cable; connection unit OMD41-a3, 100-240V ac; with cable 2m incl.software mepa in 5 langua. 2 mounting flanges with tube d=70,2mm, l=130mm, mat.st.37 2 mounting sets for flanges 2 autom.quick-acting shut-off flaps, 230V, 50/60HZ purging air unit 2bh13; with 3-ph.motor 200 to 480V, 50/60HZ incl.purging air hose,10m long
7MB1943-3BB12
COMPRESSOR GAS COOLER WITH 2 GAS DUCTS, GAS FLOW 300 L/H POWER SUPPLY AC 50/60HZ 115V; 250VA; 2.4A; WITH TEMPERATURE MONITORING, DIMENSIONS (HXWXD) 290X360X335 WITHOUT DISPOSAL OF CONDENSATION
7MB1943-0DA05
OMD41-02 dust concentration measuring equipment, with quick-acting shut-off unit 230V 50/60HZ, for stack id 2-6m tueV approved for a measuring range of extinction: 0 to 0,3 comprising: transceiver unit OMD41-m221 reflector OMD41-r21;10m connect cable; connection unit OMD41-a3, 100-240V ac; with cable 2m incl.software mepa in 5 langua. 2 mounting flanges with tube d=70,2mm, l=130mm, mat.st.37 2 mounting sets for flanges 2 autom.quick-acting shut-off flaps, 230V, 50/60HZ purging air unit 2bh13; with 3-ph.motor 200 to 480V, 50/60HZ incl.purging air hose,10m long
7MB1943-3BB14
Compressor gas cooler with 2 gas ducts, gas flow 150 l/h serial or 2x70l parallel power supply AC 50HZ;230V; 180Va; 0,8a with temperature monitoring, dimensions without disposal of
7MB1943-0DA06
OMD41-02 dust concentration measuring equipment, with quick-acting shut-off unit 230V 50/60HZ, for stack id 6-10m tueV approved for a measuring range of extinction: 0 to 0,3 comprising: transceiver unit OMD41-m221 reflector OMD41-r22;10m connect cable; connection unit OMD41-a3, 100-240V ac; with cable 2m incl.software mepa in 5 langua. 2 mounting flanges with tube d=70,2mm, l=130mm, mat.st.37 2 mounting sets for flanges 2 autom.quick-acting shut-off flaps, 230V, 50/60HZ purging air unit 2bh13; with 3-ph.motor 200 to 480V, 50/60HZ incl.purging air hose,10m long
7MB1943-3BB16
COMPRESSOR GAS COOLER WITH 2 GAS DUCTS, GAS FLOW 150 L/H SERIAL OR 2X70L PARALLEL POWER SUPPLY AC 50/60HZ; 115V 130VA; 1,3A WITH TEMPERATURE MONITORING, DIMENSIONS WITHOUT DISPOSAL OF
7MB1943-3BB20
COMPRESSOR GAS COOLER WITH 3 GAS DUCTS, GAS FLOW 300 L/H POWER SUPPLY AC 50HZ 230V; 350VA; 2.4A; WITH TEMPERATURE MONITORING, DIMENSIONS (HXWXD) 290X440X360 WITHOUT DISPOSAL OF CONDENSATION
7MB1943-3BB45
Compressor Gas cooler with 1 heat exchanger of PVDF 1 peristaltic pump for condensate removal Ambient temp.: +10 to 50 DEG C Gas outlet dew point: +5 DEG C Power supply: 230 V AC, 50Hz wall mounting enclosure Protection class: IP 20 Dimensions (WxHxD): 270x270x316 mm
7MB1943-5AA26
10-L BOTTLE WITH ONE TEST GAS COMPONENT AND N2 AS THE REMAINING GAS O2 MORE THAN 21% CALIBRATION GAS CONCENTRATION SPECIFY IN PLAIN TEXT ___%
7MB1943-0DA08
OMD41-02 dust concentration measuring equipment, with quick-acting shut-off unit 120V 50/60HZ, for stack id 0,5-2m tueV approved for a measuring range of extinction: 0 to 0,3 comprising: transceiver unit OMD41-m221 reflector OMD41-r23;10m connect cable; connection unit OMD41-a3 100-240V ac; with cable 2m incl.software mepa in 5 langua. 2 mounting flanges with tube d=70,2mm, l=130mm, mat.st.37 2 mounting sets for flanges 2 autom.quick-acting shut-off flaps, 120V, 50/60HZ purging air unit 2bh13; with 3-ph.motor 200 to 480V, 50/60HZ incl.purging air hose,length 5m
7MB1943-3BB22
COMPRESSOR GAS COOLER WITH 3 GAS DUCTS, GAS FLOW 300 L/H POWER SUPPLY AC 50/60HZ 115V; 300VA; 2.8A; WITH TEMPERATURE MONITORING, DIMENSIONS (HXWXD) 290X440X360 WITHOUT DISPOSAL OF CONDENSATION
7MB1943-0DA10
OMD41-02 dust concentration measuring equipment, with quick-acting shut-off unit 120V 50/60HZ, for stack id 2-6m tueV approved for a measuring range of extinction: 0 to 0,3 comprising: transceiver unit OMD41-m221 reflector OMD41-r21;10m connect cable; connection unit OMD41-a3 100-240V ac; with cable 2m incl.software mepa in 5 langua. 2 mounting flanges with tube d=70,2mm, l=130mm, mat.st.37 2 mounting sets for flanges 2 autom.quick-acting shut-off flaps, 120V, 50/60HZ purging air unit 2bh13; with 3-ph.motor 200 to 480V, 50/60HZ incl.purging air hose,10m long
7MB1943-3BB24
Compressor gas cooler with 4 gas ducts, gas flow 2x150l/h serial or 4x70l parallel power supply AC 50; 230V 300Va; 2,0a with temperature monitoring, dimensions (290x360x335) without disposal of
7MB1943-0DA11
OMD41-02 dust concentration measuring equipment, with quick-acting shut-off unit 120V 50/60HZ, for stack id 6-10m tueV approved for a measuring range of extinction: 0 to 0,3 comprising: transceiver unit OMD41-m221 reflector OMD41-r22-10m connect cable; connection unit OMD41-a3 100-240V ac; with cable 2m incl.software mepa in 5 langua. 2 mounting flanges with tube 2 mounting sets for flanges 2 autom.quick-acting shut-off flaps, 120V, 50/60HZ purging air unit 2bh13; with 3-ph.motor 200 to 480V, 50/60HZ incl.purging air hose,10m long
7MB1943-5AA02
10-L BOTTLE WITH ONE TEST GAS COMPONENT IN N2, NO MORE THAN 20 VPM CALIBRATION GAS CONCENTRATION SPECIFY IN PLAIN TEXT ___VPM
7MB1943-3BB32
Compressor gas cooler with 1 gas duct, explosion-proof version, gas flow 500 l/h power supply AC 50/60HZ 115V; 370Va; 4a; with temperature monitoring, degree of protection e ex de II c t4, dimensions (hxwxd) 350x470x430 without disposal of condensation