Контрольно-измерительные приборы и оборудование / 7MB
7MB2041-.....-....
ГАЗОВЫЙ АНАЛИЗАТОР КИСЛОРОДА МАЛЫХ КОНЦЕНТРАЦИЯ, 19" ШКАФНОЕ ИСПОЛНЕНИЕ
7MB1943-2BB20
Appliance socket Acc. DIN EN 175301-803, Size A for solenoid valves with power supply 12/24V
7MB1143-.....-....
ULTRAMAT 22 GAS ANALYZER FOR 2 COMPONENTS TO BE MEASURED SUITABILITY-TESTED BY TUEV, WITHOUT CONDENSATION TRAP
7MB1910-1AB03
REMOTE MEASURING HEAD, EXPLOSION-PROOF, FOR MEASURMENTS IN CORROSIVE ATMOSPHERE, NOT FOR H2 MEASUREMENT, CALIBRATED FOR ETHANE, ETHENE, ETHYLENE, BUTANE, METHANE, PROPANE, PROPYLENE, NATURAL OR CITY GAS, WITH STATEMENT OF AN EQUIVALENT CALIBRATION GAS
7MB1910-1BA1
D-8101 REMOTE MEASURING HEAD, EXPLOSION-PROOF, FOR MEASUREMENTS IN NON-CORROSIVE ATMOSPHERE, CALIBRATED FOR AMMONIA, ETHANOL ETHYLENE, ETHYLENE OXIDE, BUTANE, BUTANE/PROPANE (80/20), DICHLORETHANE, EPICHLORHYDRINE, MONOCHLORMETHANE, PROPANE, PROPYLENE, TOLUENE, VINYL CHLORIDE OR HYDROGEN, CALIBRATED IN THE RANGE 0 TO 50% OF LOWER EXPL. LIMIT
7MB1910-1CA21
REMOTE MEASURING HEAD, TWO-WIRE SYSTEM, EXPLOSION-PROOF, FOR DETECTION OF TOXIC GASES AND VAPORS COMPONENT TO BE MEASURED: CO MEASURING RANGE: 0 TO 100 VPM
7MB1943-2BC01
SOLENOID VALVE, 3/2 WAYS, STAINLESS STEEL BODY, EX-PROTECTION ACC. TO ATEX CODE II 2G EEX EM II T4 AND II 2D IP65 T=135 DEG C WITH TERMINAL BOX AND CABLE GLAND M20 X 1,5, WITHOUT FUSE, POWER SUPPLY 24V DC GAS CONNECTIONS G1/4 FEMALE
7MB1943-1QB01-1AC6
Cylinder Pressure Regulator dual stage 0-1,5 bar outlet pressure Nickel plated brass/FKM Primary contact- and standard sec. pressure gauge Cylinder connection: DIN 477 No. 14 calibration gas Outlet conn.: 6 mm fitting
7MB1943-2AA02
LENGTH-DEPENDENT DATA FOR TEMPERATURE-CONTROLLED, HEATED SAMPLE GAS LINE FOR OPERATING TEMPERATURES UP TO 200C CAN NOT BE SHORTENED PTFE HOSE 6/8MM, OUTER SHEATH: POLYAMIDE CORRUGATED HOSE DELIVERY UNIT: 1M PREASSEMBLY REQUIRED
7MB1950-.....-....
Set GGA system (generatorgas analyzer) with redundant Calomat 6E analyzers for control of hydrogen in turbo generators, measuring components, Ar/CO2 in Air, H2 in Ar/CO2, H2 in Air (smallest range: 80-100%) . Serial-Nr. Calomaten: + 1 Satz Dokumentation in Ordner 1 Satz Dokumentation auf CD-ROM
7MB1943-2AC21
STAINLESS STEEL FILTER HOUSING WITH PTFE SEALING, CONNECTIONS 1/4'' NPT FEMALE THREAD
7MB1943-6EA18-0K
LEL EXMONITOR HC 150-M FOR ACETYLENE DETECTION FOR USE IN HAZARDOUS AREA ZONE 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR ACETYLENE (C2H2) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54
7MB1943-6EA45
EMERGENCY POWER SUPPLY NV24/110 WITH CHARGER AND 2 ACCUS 12V/2.2AH FOR SUPPLY OF 8022 EVALUATION UNITS WITH 24V DC EMERGENCY SUPPLY POWER SUPPLY: 110V AC OUTPUT: 24V DC; HOUSING FOR RAIL MOUNTING 35MM
7MB1943-6EA55
MINIATURE FIELD DISTRIBUTOR KFV2 TO ACCOMMODATE TWO 8022 EVALUATION UNIT, INCLUDING INSTALLATION AND WIRING; PROTECTION RATING: IP54 DIMENSIONS: 360X254X110MM
7MB1943-6EA68
Flashing lamp ip 54 cap color red for indoor and sheltered outdoor installation thermoplast housing flash energy 5 joules 24 V dc 0.35 a
7MB1943-6EA71
Eex signal horn ip 66 for indoor and outdoor instal. degree of prot.ip 66 to iec 529 without mouth piece, 105 db(a), 1 m type of protection: eex de cT6 ptb approval ex-95.d.1010 housing: seawater-resistant aluminium inner sheath, outside high-quality polyurethane temperature range: -20 to +40 deg. c weight: 7.6 kg 24 V dc 0.3 a
7MB1943-6EB01
EXMONITOR TOX CO-1000 GAS DETECTOR FOR CARBON MONOXIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-300PPM CO OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
7MB1943-6EB03
EXMONITOR TOX H2S-100 GAS DETECTOR FOR HYDROGEN SULFIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-100PPM H2S OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
7MB1943-6EB05
EXMONITOR TOX H2-1000 GAS DETECTOR FOR HYDROGEN, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-1000PPM H2 OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
7MB1943-6EB12
EXMONITOR TOX NH3-200 GAS DETECTOR FOR AMMONIA FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-200PPM NH3 OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
7MB1943-6EC02
MINICAN CALIB. GAS CYLINDER O2 ALUMINIUM, NON-RETURNABLE CYLINDER WITH 1 LITTER CONTENT. GAS MIXTURE CONSISTING OF SYNTHETIC AIR THE WITH CALIBRATION COMPONENT CONCENTRATION OF 20VOL% OXYGEN
7MB1943-6EC03
MINICAN CALIB. GAS CYLINDER FOR CO ALUMINIUM, NON-RETURNABLE CYLINDER WITH 1 LITTER CONTENT. GAS MIXTURE CONSISTING OF THE CALIBRATION COMPONENT CO WITH A CONCENTRATION OF 300PPM BALANCED IN NITROGEN
7MB1943-7AA01
DUST CONCENTRATION MEASURING DEVICE D-R 290 FOR MEASUREMENT PATHS UP TO 2.25 M, CONSISTING OF 1 MEASURING HEAD WITH 2 M CABLE 1 REFLECTOR, 2 WELDING-TYPE PIECES WITH ADJUSTMENT FLANGE, 1 OPER. UNIT IN WALL-HOUSING, 1 FAN 115/230 V, 50/60 HZ, HOSE LENGTH 10 M
7MB1943-5AA11
10-L BOTTLE WITH 2 TEST GAS COMPONENTS IN N2, CO MORE THAN 10 VPM, O2 LESS THAN 21% CALIBRATION GAS CONCENTRATION 1 SPECIFY IN PLAIN TEXT ___VPM CALIBRATION GAS CONCENTRATION 2 SPECIFY IN PLAIN TEXT ___%