Distribution class surge arresters / 3EK surge arresters

Продукт:
Цена:

3EK7210-4CD4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=21KV, UC=16.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 55.7KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 605MM HEIGHT 240MM SHORT TERM LOAD SSL 2080N CARDBOARD PACKAGING

по запросу

3EK4120-1CC4

SURGE ARRESTER 3EK4 FOR DISTRIBUTION NETWORKS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=12KV, UC=9.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 31.8KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 420MM HEIGHT 137MM SHORT TERM LOAD SSL 1820N

по запросу

3EK7090-4CB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=9KV, UC=7.2KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 23.9KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 372MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING

по запросу

3EK7090-3AB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=9.0KV, MCOV=7.65KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 28.1KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING

по запросу

3EK7090-4AB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=9.0KV, MCOV=7.65KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 23.9KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING

по запросу

3EK7150-4CC4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=15KV, UC=12.0KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 39.8KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 485MM HEIGHT 200MM SHORT TERM LOAD SSL 2500N CARDBOARD PACKAGING

по запросу

3EK7105-4CB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=10.5KV, UC=8.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 27.8KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 372MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING

по запросу

3EK7180-3AD4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=18KV, MCOV=15.3KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 55.9KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 23.8INCH HEIGHT 9.4INCH MDCL 328LBF CARDBOARD PACKAGING

по запросу

3EK7180-4AE4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=18KV, MCOV=15.3KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 47.8KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 30.5INCH HEIGHT 10.6NCH MDCL 291LBF CARDBOARD PACKAGING

по запросу

3EK7120-4AD4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=12KV, MCOV=10.2KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 31.9KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 23.8INCH HEIGHT 9.4INCH MDCL 328LBF CARDBOARD PACKAGING

по запросу

3EK7120-4CC4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=12KV, UC=9.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 31.8KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 485MM HEIGHT 200MM SHORT TERM LOAD SSL 2500N CARDBOARD PACKAGING

по запросу

3EK7120-3AC4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=12KV, MCOV=10.2KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 37.3KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 19.1INCH HEIGHT 7.9INCH MDCL 393LBF CARDBOARD PACKAGING

по запросу

3EK4210-1CJ4

SURGE ARRESTER 3EK4 FOR DISTRIBUTION NETWORKS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=21KV, UC=16.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 55.7KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 690MM HEIGHT 204MM SHORT TERM LOAD SSL 1220N

по запросу

3EK7030-4CB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=3KV, UC=2.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 8.0KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 372MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING

по запросу

3EK7030-3AB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=3.0KV, MCOV=2.55KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 9.5KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING

по запросу

3EK7030-4AB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=3.0KV, MCOV=2.55KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 8.0KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING

по запросу

3EK7060-4CB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=6KV, UC=4.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 15.9KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 372MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING

по запросу

3EK7060-3AB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=6.0KV, MCOV=5.10KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 19.6KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING

по запросу

3EK7100-4AC4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=10KV, MCOV=8.40KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 26.6KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 19.1INCH HEIGHT 7.9INCH MDCL 393LBF CARDBOARD PACKAGING

по запросу

3EK7100-3AB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=10KV, MCOV=8.40KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 29.4KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING

по запросу

3EK7150-3AD4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=15KV, MCOV=12.7KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 46.6KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 23.8INCH HEIGHT 9.4INCH MDCL 328LBF CARDBOARD PACKAGING

по запросу

3EK7300-3AH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=30KV, MCOV=24.4KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 87.8KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 48.4INCH HEIGHT 15.7INCH MDCL 197LBF CARDBOARD PACKAGING

по запросу

3EK7300-4AH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=30KV, MCOV=24.4KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 79.7KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 48.4INCH HEIGHT 15.7INCH MDCL 197LBF CARDBOARD PACKAGING

по запросу

3EK7300-4CF4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=30KV, UC=24.0KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 79.5KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 900MM HEIGHT 300MM SHORT TERM LOAD SSL 1660N CARDBOARD PACKAGING

по запросу

3EK7450-4CH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=45KV, UC=36.0KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 119KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING

по запросу

3EK7420-4CH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=42KV, UC=33.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 111KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING

по запросу

3EK7540-4CJ4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=54KV, UC=43.2KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 143KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1420MM HEIGHT 470MM SHORT TERM LOAD SSL 1060N CARDBOARD PACKAGING

по запросу

3EK7600-4CJ4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=60KV, UC=48.0KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 159KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1420MM HEIGHT 470MM SHORT TERM LOAD SSL 1060N CARDBOARD PACKAGING

по запросу

3EK7220-4CD4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=22KV, UC=17.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 58.3KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 605MM HEIGHT 240MM SHORT TERM LOAD SSL 2080N CARDBOARD PACKAGING

по запросу

3EK7270-3AF4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=27KV, MCOV=22.0KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 79.7KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 35.4INCH HEIGHT 11.8INCH MDCL 262LBF CARDBOARD PACKAGING

по запросу

3EK7270-4AH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=27KV, MCOV=22.0KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 71.8KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 48.4INCH HEIGHT 15.7INCH MDCL 197LBF CARDBOARD PACKAGING

по запросу

3EK7270-4CE4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=27KV, UC=21.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 71.6KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 775MM HEIGHT 270MM SHORT TERM LOAD SSL 1850N CARDBOARD PACKAGING

по запросу

3EK7240-4CE4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=24KV, UC=19.2KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 63.6KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 775MM HEIGHT 270MM SHORT TERM LOAD SSL 1850N CARDBOARD PACKAGING

по запросу

3EK7240-3AF4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=24KV, MCOV=19.5KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 70.5KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 35.4INCH HEIGHT 11.8INCH MDCL 262LBF CARDBOARD PACKAGING

по запросу

3EK7240-4AH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=24KV, MCOV=19.5KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 63.8KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 48.4INCH HEIGHT 15.7INCH MDCL 197LBF CARDBOARD PACKAGING

по запросу

3EK7360-4CH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=36KV, UC=28.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 95.4KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING

по запросу

3EK7360-3AH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=36KV, MCOV=29.0KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 108KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 48.4INCH HEIGHT 15.7INCH MDCL 197LBF CARDBOARD PACKAGING

по запросу

3EK7360-4AK4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=36KV, MCOV=29.0KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 95.7KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 62.8INCH HEIGHT 20.1INCH MDCL 154LBF CARDBOARD PACKAGING

по запросу

3EK7330-4CH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=33KV, UC=26.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 87.5KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING

по запросу

3EK7330-3AH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=33KV, MCOV=27.5KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 98.4KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 48.4INCH HEIGHT 15.7INCH MDCL 197LBF CARDBOARD PACKAGING

по запросу

3EK7330-4AJ4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=33KV, MCOV=27.5KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 87.7KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 55.9INCH HEIGHT 18.5INCH MDCL 167LBF CARDBOARD PACKAGING

по запросу

3EK7060-4AB4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=6.0KV, MCOV=5.10KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 15.9KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING

по запросу

3EK7480-4CH4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=48KV, UC=38.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 127KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING

по запросу

3EK7510-4CJ4

SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=51KV, UC=40.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 135KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1420MM HEIGHT 470MM SHORT TERM LOAD SSL 1060N CARDBOARD PACKAGING

по запросу

3EK4180-1CJ4

SURGE ARRESTER 3EK4 FOR DISTRIBUTION NETWORKS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=18KV, UC=14.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 47.7KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 690MM HEIGHT 204MM SHORT TERM LOAD SSL 1220N

по запросу

3EK4270-1CK4

SURGE ARRESTER 3EK4 FOR DISTRIBUTION NETWORKS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=27KV, UC=21.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 71.6KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 820MM HEIGHT 234MM SHORT TERM LOAD SSL 1060N

по запросу

3EK4240-1CK4

SURGE ARRESTER 3EK4 FOR DISTRIBUTION NETWORKS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=24KV, UC=19.2KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 63.6KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 820MM HEIGHT 234MM SHORT TERM LOAD SSL 1060N

по запросу

3EK4300-1CM4

SURGE ARRESTER 3EK4 FOR DISTRIBUTION NETWORKS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=30KV, UC=24.0KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 79.5KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 960MM HEIGHT 270MM SHORT TERM LOAD SSL 920N

по запросу

3EK4360-1CR4

SURGE ARRESTER 3EK4 FOR DISTRIBUTION NETWORKS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=36KV, UC=28.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 95.4KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1200MM HEIGHT 320MM SHORT TERM LOAD SSL 780N

по запросу

3EK4060-1CB4

SURGE ARRESTER 3EK4 FOR DISTRIBUTION NETWORKS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=6KV, UC=4.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 15.9KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 280MM HEIGHT 96MM SHORT TERM LOAD SSL 2600N

по запросу

Не нашли что искали? Позвоните нам по телефону +7(812)385-50-34 | 8(800)555-97-29 или Оформите заявку, наши специалисты ответят на ваш вопрос.

Серия оборудования 3EK surge arresters SIEMENS представляет собой ограничители перенапряжения. Это специальные устройства, состоящие из набора изоляторов на одной резьбовой оси. Данные устройства применяются в цепях, где присутствует опасность возникновения перенапряжения. Прибор при увеличении разности потенциалов поглощает часть энергии и рассеивает ее в виде тепловой энергии. Для этого он снабжен набором охлаждающих элементов. В каталоге имеются ограничители перенапряжения на разные величины напряжений от 2,4 кВ до 30 и более. Также защитные устройства имеются с открытыми и закрытыми ребрами для охлаждения. При выборе прибора 3EK surge arresters SIEMENS также необходимо учитывать предельный ток, на который он рассчитан. Большинство аппаратов спроектированы на 10 кА, но также имеются в наличии устройства с более высокими значениями тока. Все аппараты снабжены одинаковым типом крепления – шпилька с резьбой. Устройства изготовлены из стойких к коррозии материалов и окрашены защитными покрытиями. На все ограничители в каталоге производитель Сименс дает гарантию, по вопросам которой клиенты могут обратиться к нам в любое время. Также любой товар из нашего ассортимента может быть доставлен в любое время.