Surge arresters with high energy discharge capability / 3EJ surge arresters

Продукт:
Цена:

3EJ0003-6CB71-0

3EJ0 surge arresters for medium-voltage networks for indoor use Applied standard: IEC60099-4 Ur: 3.6 kV, Uc: 3.2 kV Ures (250A, 30/60µs): 7.9 kV Ures (500A, 30/60µs): 8.0 kV Charge transfer rating Qs: 0.4C Rated thermal energy Wth: 1.0kJ/kV Rated short circuit current Is: 20 kA Creepage distance: 162 MM Height: 170 MM Cardboard packaging

по запросу

3EJ0004-8CB71-0

3EJ0 surge arresters for medium-voltage networks for indoor use Applied standard: IEC60099-4 Ur: 4.8 kV, Uc: 4.3 kV Ures (250A, 30/60µs):9.8 kV Ures (500A, 30/60µs): 10.0 kV Charge transfer rating Qs: 0.4C Rated thermal Energy Wth:1.0kJ/kV Rated short circuit current Is: 20 kA Creepage distance: 162 MM Height: 170 MM Cardboard packaging

по запросу

3EJ0007-2CB71-0

3EJ0 surge arresters for medium-voltage networks for indoor use Applied standard: IEC60099-4 Ur: 7.2 kV, Uc: 6.5 kV Ures (250A, 30/60µs):14.9 kV Ures (500A, 30/60µs): 15.0 kV Charge transfer rating Qs: 0.4C Rated thermal Energy Wth:1.0kJ/kV Rated short circuit current Is: 20 kA Creepage distance: 162 MM Height: 170 MM Cardboard packaging

по запросу

3EJ0012-0CC71-0

3EJ0 surge arresters for medium-voltage networks for indoor use Applied standard: IEC60099-4 Ur: 12 kV, Uc: 10.6 kV Ures (250A, 30/60µs):24.7 kV Ures (500A, 30/60µs): 25.0 kV Charge transfer rating Qs: 0.4C Rated thermal Energy Wth:1.0kJ/kV Rated short circuit current Is: 20 kA Creepage distance: 191 MM Height: 200 MM Cardboard packaging

по запросу

3EJ0015-0CC71-0

3EJ0 surge arresters for medium-voltage networks for indoor use Applied standard: IEC60099-4 Ur: 15 kV, Uc: 13.3 kV Ures (250A, 30/60µs):30.6 kV Ures (500A, 30/60µs): 31.0 kV Charge transfer rating Qs: 0.4C Rated thermal Energy Wth:1.0kJ/kV Rated short circuit current Is: 20 kA Creepage distance: 191 MM Height: 200 MM Cardboard packaging

по запросу

3EJ2001-5CB31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 Ur: 1.5 kV, Uc: 1.2kV Nominal discharge current In: 10 kA Ures (10kA, 8/20µs): 3.5 kV Charge transfer rating Qrs: 2.0C Rated thermal energy Wth: 7.0kJ/kV Rated short circuit current Is: 50 kA Creepage distance: 430 MM Height: 166 MM Cardboard packaging

по запросу

3EJ2003-0CB31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=3.0KV, UC=2.4KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 7.1KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 430 MM HEIGHT 166 MM CARDBOARD PACKAGING

по запросу

3EJ2004-5CB31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=4.5KV, UC=3.6KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 10.6KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 430 MM HEIGHT 166 MM CARDBOARD PACKAGING

по запросу

3EJ2006-0CB31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=6.0KV, UC=4.8KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 14.1KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 430 MM HEIGHT 166 MM CARDBOARD PACKAGING

по запросу

3EJ2007-5CC31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=7.5KV, UC=6.0KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 17.6KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 590 MM HEIGHT 211 MM CARDBOARD PACKAGING

по запросу

3EJ2010-5CC31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=10.5KV, UC=8.4KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 24.7KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 590 MM HEIGHT 211 MM CARDBOARD PACKAGING

по запросу

3EJ2012-0CC31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=12KV, UC=9.6KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 28.2KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 590 MM HEIGHT 211 MM CARDBOARD PACKAGING

по запросу

3EJ2015-0CD31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=15KV, UC=12.0KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 35.3KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 750 MM HEIGHT 256 MM CARDBOARD PACKAGING

по запросу

3EJ2018-0CD31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=18KV, UC=14.4KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 42.3KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 750 MM HEIGHT 256 MM CARDBOARD PACKAGING

по запросу

3EJ2021-0CD31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=21KV, UC=16.8KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 49.4KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 750 MM HEIGHT 256 MM CARDBOARD PACKAGING

по запросу

3EJ2024-0CE31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=24KV, UC=19.2KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 56.4KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 920 MM HEIGHT 301 MM CARDBOARD PACKAGING

по запросу

3EJ2027-0CE31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=27KV, UC=21.6KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 63.5KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 920 MM HEIGHT 301 MM CARDBOARD PACKAGING

по запросу

3EJ2030-0CF31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=30KV, UC=24.0KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 70.5KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 1090 MM HEIGHT 346 MM CARDBOARD PACKAGING

по запросу

3EJ2036-0CG31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=36KV, UC=28.8KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 84.6KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 1250 MM HEIGHT 391 MM CARDBOARD PACKAGING

по запросу

3EJ2042-0CG31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=42KV, UC=33.6KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 98.7KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 1250 MM HEIGHT 391 MM CARDBOARD PACKAGING

по запросу

3EJ2045-0CH31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=45KV, UC=36.0KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 106KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 1420 MM HEIGHT 436 MM CARDBOARD PACKAGING

по запросу

3EJ2048-0CH31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=48KV, UC=38.4KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 113KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 1420 MM HEIGHT 436 MM CARDBOARD PACKAGING

по запросу

3EJ2051-0CJ31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=51KV, UC=40.8KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 120KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 1580 MM HEIGHT 481 MM CARDBOARD PACKAGING

по запросу

3EJ2054-0CJ31-4

3EJ2 surge arresters for medium-voltage networks for outdoor use Applied standard: IEC60099-4 UR=54KV, UC=43.2KV NOMINAL DISCHARGE CURRENT 10 KA URES (10kA, 8/20) = 127KV CHARGE TRANSFER RATING 2.0C RATED THERMAL ENERGY 7.0KJ/KV RATED SHORT CIRCUIT CURRENT 50KA CREEPAGE DISTANCE 1580 MM HEIGHT 481 MM CARDBOARD PACKAGING

по запросу

3EJ3001-4CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=1.4KV, UC=1.1KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 3.2KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3001-8CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=1.8KV, UC=1.4KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 4.1KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3002-0CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=2.0KV, UC=1.6KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 4.5KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3002-5CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=2.5KV, UC=2.0KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 5.6KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3003-0CB41-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=3.0KV, UC=2.4KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 6.8KV CHARGE TRANSFER RATING 2.8C THERMAL ENERGY RATING 10KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3003-0CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=3.0KV, UC=2.4KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 6.8KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3003-4CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=3.4KV, UC=2.7KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 7.7KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3004-0CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=4.0KV, UC=3.2KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 9.0KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3004-5CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=4.5KV, UC=3.6KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 10.1KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3004-8CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=4.8KV, UC=3.8KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 10.8KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3005-2CB51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=5.2KV, UC=4.2KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 11.7KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3006-0CB41-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=6.0KV, UC=4.8KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 13.5KV CHARGE TRANSFER RATING 2.8C THERMAL ENERGY RATING 10KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 390MM HEIGHT 172MM CARDBOARD PACKAGING

по запросу

3EJ3006-0CC51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=6.0KV, UC=4.8KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 13.5KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 550MM HEIGHT 208MM CARDBOARD PACKAGING

по запросу

3EJ3006-3CC51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=6.3KV, UC=5.0KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 14.2KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 550MM HEIGHT 208MM CARDBOARD PACKAGING

по запросу

3EJ3007-6CC51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=7.6KV, UC=6.1KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 17.1KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 550MM HEIGHT 208MM CARDBOARD PACKAGING

по запросу

3EJ3008-6CC51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=8.6KV, UC=6.9KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 19.4KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 550MM HEIGHT 208MM CARDBOARD PACKAGING

по запросу

3EJ3010-5CC41-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=10.5KV, UC=8.4KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 23.6KV CHARGE TRANSFER RATING 2.8C THERMAL ENERGY RATING 10KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 550MM HEIGHT 208MM CARDBOARD PACKAGING

по запросу

3EJ3010-5CC51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=10.5KV, UC=8.4KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 23.6KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 550MM HEIGHT 208MM CARDBOARD PACKAGING

по запросу

3EJ3012-0CC41-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=12KV, UC=9.6KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 27.0KV CHARGE TRANSFER RATING 2.8C THERMAL ENERGY RATING 10KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 550MM HEIGHT 208MM CARDBOARD PACKAGING

по запросу

3EJ3012-0CD51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=12KV, UC=9.6KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 27.0KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 700MM HEIGHT 244MM CARDBOARD PACKAGING

по запросу

3EJ3012-4CD51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=12.4KV, UC=9.9KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 27.9KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 700MM HEIGHT 244MM CARDBOARD PACKAGING

по запросу

3EJ3015-0CD41-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=15KV, UC=12.0KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 33.8KV CHARGE TRANSFER RATING 2.8C THERMAL ENERGY RATING 10KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 700MM HEIGHT 244MM CARDBOARD PACKAGING

по запросу

3EJ3015-0CD51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=15KV, UC=12.0KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 33.8KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 700MM HEIGHT 244MM CARDBOARD PACKAGING

по запросу

3EJ3018-0CD41-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=18KV, UC=14.4KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 40.5KV CHARGE TRANSFER RATING 2.8C THERMAL ENERGY RATING 10KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 700MM HEIGHT 244MM CARDBOARD PACKAGING

по запросу

3EJ3018-0CE51-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=18KV, UC=14.4KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 40.5KV CHARGE TRANSFER RATING 3.6C THERMAL ENERGY RATING 14KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 860MM HEIGHT 281MM CARDBOARD PACKAGING

по запросу

3EJ3021-0CE41-4

SURGE ARRESTER 3EJ3 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=21KV, UC=16.8KV NOMINAL DISCHARGE CURRENT 20KA URES (10KA, 8/20) = 47.3KV CHARGE TRANSFER RATING 2.8C THERMAL ENERGY RATING 10KJ/KV SHORT-CIRCUIT CURRENT 65KA CREEPAGE DISTANCE 860MM HEIGHT 281MM CARDBOARD PACKAGING

по запросу

Не нашли что искали? Позвоните нам по телефону +7(812)385-50-34 | 8(800)555-97-29 или Оформите заявку, наши специалисты ответят на ваш вопрос.

В данном разделе нашего каталога представлены защитные компоненты, выполняющие роль блокирующего устройства в случае возникновения высоких уровней напряжения на входе. Компоненты серии 3EJ surge arresters – это ограничители перенапряжения. Их устанавливают в цепях питания трехфазной или однофазной нагрузки, в качестве которой может быть асинхронный двигатель, электронное чувствительное к перепадам устройство или измерительный прибор. Устройство выполняет комплексные защитные функции, обеспечивая защиту от короткого замыкания short circuit current rating, предотвращая сильную аварию, минимизируя пути утечки creepage distance тока. Без этого компонента невозможен безопасный пуск любого оборудования, каким бы оно мощным не было. В каталоге представлен большой выбор surge suppressor ограничителей перенапряжения, которые отличаются между собой по многочисленным параметрам. Выбор данного изделия выполняется по величине максимального напряжения. Оно может быть от 1,5 кВ до 35 и более кВ. Обращаем ваше внимание на то, что величина максимального напряжения зависит от действующего тока и времени, в течение которого он оказывал влияние на линию. Также следует обращать внимание на максимальный ток и пути утечки. Устройства 3EJ на 31 кВ обладают кратчайшим путем утечки 191 мм. Чтобы приобрести защитный компонент, звоните нам в любое удобное время или оставляйте свои контакты в форме на сайте.