Автоматизация / A1D

Продукт
Цена

A1D00326152-01

PULL RELIEF TypeKK2

По запросу

A1D00326164-01

GAUGE FOR STAR

По запросу

A1D00321829-02

DISTANCE PLATE

По запросу

A1D00326183-01

BUSH EPG.1B.307.HLN

По запросу

A1D00322256-01

CABLE FOR PORTAL (OPTICAL)

По запросу

A1D00327466-01

BNC-FINAL RESISTOR 50 OHM

По запросу

A1D00322257-01

CABLE FOR PORTAL HEAD AXIS

По запросу

A1D00322258-01

CABLE FOR PORTAL CAN-BUS

По запросу

A1D00194422-02

Preventive Maintenance SIPLACE X-series, Edition 07/2005, English

По запросу

A1D00305781-01

DIN 988-6x12x0.2-St 2 K 50

По запросу

A1D00329526-01

TOOTHED BELT LP-TRANSPORT 400 S50

По запросу

A1D00329565-01

PROTECTION S50 FRAME PROFILE LEFT REWORK

По запросу

A1D00322863-01

RETROFIT KIT COMPRESSED AIR DIS TRIBUTOR

По запросу

A1D00191963-02

Instructions for Mounting the Star on the DLM1 Placement Head SIPLACE S23/HS50, Edition 07/00, German+English

По запросу

A1D00304632-05

CENTERING BOLT

По запросу

A1D00304641-01

SPACER PLATE

По запросу

A1D00330464-04

SIPLACE Tools and Test Equipment Box

По запросу

A1D00116933S03

ESS Docking Unit for COTF-X (HW)

По запросу

A1D00119787-01

The vacuum pump can be connected to a SIPLACE X4I, X4, if the machine is equipped with a vacuum pump installation kit (Ordering number 11978 6 for X4 und 119797 for X4I). The vacuum pump can be used, if the mach ine is using C&P20A heads in combination with station SW 702 or higher. The usage in combination with CPP- or Twin head is not possibl e.

По запросу

A1D00116927

The WLAN CLIENT MODULE (Hardware) is needed for the communicaton between the SIPLACE LAN and the wireless (WLAN) Scanner Network. NOTE: The number of WLAN CLIENT MODULES has to be determined in a factory prior to the install.

По запросу

A1D00119795

The vacuum pump can be connected to SIPLACE X4, SIPLACE X3 and SIPLACE X2, if the placement stations are equipped with the Option Retrofit vacuum pump. Voltage 110 V (3-208V). This pump is only required when 20 nozzle Collect & Place Heads are used. For all other head combinations also the pump under item number 119017 can be used.

По запросу

A1D00363169-01

Socket wrench Set 15mm 1/2Zoll 6K.

По запросу

A1D00313732-01

CROWN GEAR

По запросу

A1D00116931

This option for the X-Series contains a CANBus-Card with CANBus-cables and is required for communication between Ess-PC (116366 SIPLACE Pro desktop hardware + OS) and Ess-Docking Station. Ess-Docking Station for Changeover table X-Series (116933).Ess (Externe setup station).Ess-PC and Ess-Docking Station has to be ordered separately.

По запросу

A1D00119788-01

THE OFFLINE TEACH STATION SIPLA CE X/D-SERIES SIMPLIFIES THE PR OCESS OFCREATING VISION FILES ( GFS) OFFLINE. THE COMPONENT VIS ION FILE ISCREATED USING THE AC TUAL COMPONENT WHICH IS IMAGED PROCESSED USING THE COMPONENT C AMERA. FOLLOWING THIS THE COMPO NENT DESCRIPTION (GF) ISEXPORTE D TO THE SIPLACE PRO DATABASE. THE OFFLINE TEACH STATION COMES WITH THE COMPUTER, ADJUSTABLE C OMPONENT SUPPORT PLATE, CAMERA MOUNTINGTOWER, COMPONENT VISION CAMERA, DOCUMENTATION AND SOFT WARE PACKAGE. THECAMERA TYPE IS CONFIGURED ACCORDING TO CUSTOM ER REQUIREMENTS. ALLSIPLACE X/D -SERIES COMPONENT CAMERAS ARE A VAILABLE:C+P 20 CAMERA,C+P 12CA

По запросу

A1D00116933

Docking station for provision of an infrastructure for communication between the PC of the Setup Center and the X-Feeder modules. Stand alone operation allows the X-Feeders to be supplied with power. Can be set to the SMEMA heights 830/ 900/ 930/ 950 mm. Line voltage: 88-264V. Compressed air pressure: 5-10 bar.

По запросу

A1D00119790

To use a vacuum pump in SIPLACE X-Series with the 20 nozzle Collect & Place head this retrofit kit is necessary. Using a vacuum pump will reduce the air consumption of SIPLACE X4 with 4times 20 nozzle Collect & Place Head from 990 Nl/min to 285 Nl/min. Per head one retrofit kit is necessary. In case the 6 or 12 nozzle Collect & Place heads are also used on the machine, these heads need to be retrofitted also (item number 119796). In addition one machine retrofit kit is required. The retrofit kits are necessary for new machine order as well as for retrofit in field. Requirement is station SW 603. Station SW 604 and higher is not possible. If use the vacuum pump the maximum placement rate of the 20 nozzle Collect & Place Head is 20,000 cph.

По запросу

A1D00119791

The retrofit kit is necessary to use a vacuum pump with SIPLACE X4. The use of a vacuum pump reduces the air consumption. In addition one head reconfiguration kit per collect and place head is required.The retrofit kits are necessary for new machine order as well as for retrofit in field. To guarantee the specification of the SIPLACE machine the vacuumpump must fulfill the specification of Siemens. More details from the respective Sales or Service representative. The vacuum pump don't work with SR SW 604 and SR SW 605 in combination with cp20.

По запросу

A1D00116935

SIPLACE Splice Detection Hub for Table Controller: This item is needed t o prepare a SIPLACE station for splice detection. It contains a hub for connection of up to 2 table controllers for SIPLACE S/F. Also, cabling a nd mounting material is included. Additionally, the respective table con troller(s) and splice sensors need to be ordered.

По запросу

A1D00116936

SIPLACE Splice Detection Hub for Table Controller: This item is needed t o prepare a SIPLACE station for splice detection. It contains a hub for connection of up to 4 table controllers for SIPLACE HS-xx. Also, cabling and mounting material is included. Additionally, the respective table c ontroller(s) and splice sensors need to be ordered.

По запросу

A1D00119794

The vacuum pump can be connected to SIPLACE X4, SIPLACE X3, SIPLACE X2 and SIPLACE D3, if the placement stations are equipped with the Option Retrofit vacuum pump. Voltage 50Hz 220V (3-400V). This pump is only required when 20 nozzle Collect & Place Heads are used. For all other head combinations also the pump under item number 119017 can be used. Not in combination with SR SW 604.

По запросу
По запросу

A1D00367216-04

SIPLACE line utility box (10/2004)

По запросу

A1D00116936-01

SIPLACE Splice Detection Hub for Table Controller: This item is needed to prepare a SIPLACE station for splice detection. It contains a hub for connection of up to 4 table controllers for SIPLACE HS-xx. Also, cabling and mounting material is included. Additionally, the respective table controller(s) and splice sensors need to be ordered.

По запросу

A1D00119822

Component feeder changeover table, height 830-950mm, with integrated reel container. For SIPLACE D1/D2.Component feeder capacity (Typ S): 15 slots. With wheels for minimization of setup times.

По запросу

A1D00116951

Setup Center Basic Pkg (V3.2)

По запросу

A1D00119825

Waffle-Pack Changer for SIPLACE D1(location 1) / D3 (location 2) combined with fixed component table for transport height 830/900/930/950mm. Sofrtware requirements for D1: Programming system SIPLACE Pro 5.0, Stationsoftware 604. Software requirements for D3: Programming system SIPLACE Pro 5.2, Stationsoftware 605. Storage capacity of 28 WTC (Waffle Pack Tray Carrier), max. Size of Waffle Pack Tray 341mm x 235mm x 15mm. Tray changeover time: 1.9s (over 1 level). 10,5 feeder locations required for Waffle-Pack Changer. Supply voltages: 3-204/230V, 3-380/400/415V.

По запросу

A1D00116952

Upgrade Setup Center Package (V3.2)

По запросу

A1D00119826

Waffle-Pack Changer for SIPLACE X2 (location 2/4) / X3 (location 2) combined with fixed component table for transport height 830/900/930/950mm. Software requirements for X2/X3: Programming system SIPLACE Pro 5.2, Stationsoftware 605. Hardware requirements for X2/X3: SIPLACE X/D3 Interface BE-Wagen HF/D3 (119724). Storage capacity of 28 WTC (Waffle Pack Tray Carrier), max. Size of Waffle Pack Tray 341mm x 235mm x 15mm. Tray changeover time: 1.9s (over 1 level). 10,5 feeder locations required for Waffle-Pack Changer. Supply voltages: 3-204/230V, 3-380/400/415V.

По запросу

A1D00116952-02

Upgrade Setup Center Package (V3.2SP1) - Media Package 116954

По запросу

A1D00119827

Waffle Pack Changer for SIPLACE SX1/SX2 Supporting transport height 900/930/950mm. Storage capacity of 28 Waffle Tray Carriers, max. tray dimension is 341mm x 236mm x 15mm (standard mode). Tray changeover time: 1.9s (over 1 level). Supply voltages: 3~204/230V, 3~380/400/415V

По запросу

A1D00116953

Upgrade Setup Center Station Connection

По запросу

A1D00119833

SIPLACE Pick & Place Head for SIPLACE D1 placement station. The Pick & Place Head consist of one Pick and Place Module. Included in delivery are the digital stationary camera (type 36) and 1 Nozzle changer with 2 Standard nozzle magazine (item no.:03048676) for each 2 nozzles and 1 Soko Nozzle magazine (item no.:03048639). With this head a component range from 0603 to 85mm x 85mm could be placed. Larger components have to be tested in our application lab before to get a confirmation for a component range up to 200mm x 125mm. A maximum component height of 19mm is possible. Max. component weight: 30gr. (Standard), 100gr.(with reduced speed). Programmable placement force: 1N-15N. Camera: 80um / Pixel. Min. Ball: 320um. // Higher solution and higher range for components with stationary camera (type 33) (Item-No:119818). //.

По запросу

A1D00116953-01

Upgrade Setup Center Station Connection

По запросу

A1D00119834

SIPLACE Pick & Place Head for SIPLACE D1 placement station. The Pick & Place Head consist of one Pick and Place Module. Included in delivery are the digital stationary camera (type 36) and 1 Nozzle changer with 2 Standard nozzle magazine (item no.:03048676) for each 2 nozzles and 1 Soko Nozzle magazine (item no.:03048639). With this head a component range from 0603 to 85mm x 85mm could be placed. Larger components have to be tested in our application lab before to get a confirmation for a component range up to 200mm x 125mm. A maximum component height of 19mm is possible. Max. component weight: 30gr. (Standard), 100gr.(with reduced speed). Programmable placement force: 1N-15N. Camera: 80um / Pixel. Min. Ball: 320um. This Pick & Place Modul could only be ordered together in Configuration with a D1 single Head machine. For a D1 equipped with a C&P12 or C&P 6 and a Pick & Place Modul, Item No. 119883 has to be ordered. // Higher solution and higher range for components with stationary camera (type 33) (Item-No:119818). //.

По запросу

A1D00116961-01

PROTECTION SHIELD FOR SIPLACE P LACEMENT STATIONS 1 FEEDER LOCA TION.

По запросу

A1D00344943-02

Spring-loaded mount Exchange by trained staff

По запросу

A1D00328232-01

Key-switch

По запросу

A1D03039227-01

5V SUPPORT CABLE HS50/60

По запросу

A1D03039249-01

WASTE SLIDE

По запросу